Intraocular pressure measurement in cynomolgus monkeys. Tono-Pen versus manometry.
نویسندگان
چکیده
PURPOSE In living cynomolgus monkey eyes, the authors compared manometrically set and measured intraocular pressure (IOP) with simultaneous IOP readings obtained with the Tono-Pen (TP), a handheld applanation tonometer based on the Mackay-Marg principle. METHODS In three pentobarbital-anesthetized cynomolgus monkeys, IOP was set and measured manometrically after anterior chamber cannulation through the peripheral cornea with a 26-gauge needle connected to a vertically adjustable reservoir and a pressure transducer. Intraocular pressure was raised in approximately 5 mm Hg steps from 5 mm Hg to 60 mm Hg and then lowered in 5 mm Hg steps to 5 mm Hg, with TP measurements taken at each increment and decrement in open and stopcock modes. RESULTS Linear regression analysis of TP on manometric readings for grouped data from all six eyes, with each data point representing the average of all the TP readings from one eye at each manometric pressure setting, showed a slope 0.692 +/- 0.016 and 0.683 +/- 0.023 (both significantly different from 1; P < 0.001), intercept 1.21 +/- 0.60 and 1.64 +/- 0.82 mm Hg (both significantly different from 0.0, P < 0.05), and correlation coefficient 0.981 and 0.96 in open stopcock and closed stopcock mode, respectively. There were no striking differences when the data were analyzed for individual eyes or animals, for open versus closed stopcock manometry, or for increasing versus decreasing manometric IOP. CONCLUSIONS The TP provides reproducible measurements of IOP in cynomolgus monkeys, with measurement accuracy dependent on the generation of an appropriate calibration curve.
منابع مشابه
Repeatability, reproducibility and agreement of intraocular pressure measurement in rabbits by the TonoVet and Tono-Pen
Tono-Pen and TonoVet have been used in rabbits to measure intraocular pressure (IOP) and investigate the effect of IOP lowering therapies. Therefore, their reliability and accuracy are very important and deserve careful evaluation. Our results showed that the with-subject deviation (Sw) and intraclass correlation coefficient (ICC) of the TonoVet and Tono-Pen were 0.61 mmHg/0.83 mmHg and 0.97/0....
متن کاملIntraocular pressure measurement after penetrating keratoplasty: minified Goldmann applanation tonometer, pneumatonometer, and Tono-Pen versus manometry.
The accuracy of intraocular pressure measurement with the minified Goldmann applanation tonometer, the pneumatonometer, and the Tono-Pen tonometer were compared in post-mortem human eyes which had undergone penetrating keratoplasty. Enucleated post-mortem human eyes underwent same sized (7.75 mm) or 0.5 mm oversized (8.25 mm) autologous penetrating keratoplasty. Intraocular pressure was then se...
متن کاملTono-Pen XL tonometry during application of a suction ring in rabbits
BACKGROUND The purpose of this study is to evaluate the use of Tono-Pen XL in measuring IOP during the application of a suction ring in rabbit eyes with manometrically controlled IOP. METHODS Tono-Pen XL was calibrated against direct manometry in 10 rabbit eyes. A suction ring was then applied in 4 rabbit eyes and the IOP was determined manometrically during suction ring application at 350 mm...
متن کامل® calibration curves for cats, cows and sheep
The objective of this study was to provide calibration curves for correcting intraocular pressure (IOP) measurements obtained using the Tono-Pen XL ® tonometer in cats, cows and sheep. Twelve eyes from 9 cats, 13 eyes from 7 cows, 10 eyes from 5 sheep were used. The anterior chamber of the eye was cannulated in vivo , in situ (immediately post mortem) or ex vivo with a fine needle and IOP was v...
متن کاملComparisons of the Tono-Pen® and Goldmann Applanation Tonometer in the Measurement of Intraocular Pressure of Primary Open Angle Glaucoma Patients in a Hospital Population in Southwest Nigeria
OBJECTIVE The aim of this study was to compare intraocular pressure (IOP) measured with the Tono-Pen® to that measured using the Goldmann applanation tonometer (GAT) in patients with primary open angle glaucoma attending a glaucoma clinic. SUBJECTS AND METHODS A comparative clinic-based observational study was conducted involving 75 patients (39 men and 36 women) attending a glaucoma clinic i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 37 6 شماره
صفحات -
تاریخ انتشار 1996