Quantitative cerebral perfusion with SCALE-PWI: Accelerated image acquisition and optimized image reconstruction

نویسندگان

  • J. J. Mouannes
  • W. Shin
  • S. Shah
  • A. Sen
  • S. Maheshwari
  • T. J. Carroll
چکیده

INTRODUCTION Quantitative cerebral perfusion is a fundamental physiologic parameter that reflects the severity and progression of a broad range of pathologies, such as stroke, cancer, Alzheimer’s Disease, cerebrovascular occlusive disease, and multiple sclerosis. An accelerated and simplified implementation of the multi-scan Bookend technique [1,2], which has been shown to provide reproducible, reliable and accurate quantitative cerebral perfusion values [2,3], has been made possible through a SelfCALibrated Epi Perfusion Weighted Imaging (SCALE-PWI) MRI pulse sequence [4]. In one sequence, SCALE-PWI acquires inversion recovery (IR) Look-Locker (LL) EPI modules for a single “calibration” slice containing white matter (WM), before and after a conventional gradient-echo (GRE) EPI dynamic susceptibility contrast (DSC) scan with a gadolinium-based contrast bolus injection, resulting in a total scan time under 2 minutes. SCALE-PWI eliminates the need for technologist training, reduces motion artifacts, and provides the possibility of on-site, inline reconstruction of quantitative images of cerebral perfusion. A study of two different delay times between consecutive SCALE-PWI modules and a water exchange correction parameterization for SCALE-PWI at 1.5 T are presented in this work, which results in accelerating image acquisition and making quantitative perfusion reconstruction of SCALE-PWI more robust and ready for use in clinical settings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correction algorithm for singular value decomposition artifact in quantitative cerebral perfusion images using SCALE-PWI

INTRODUCTION Quantitative cerebral perfusion has been achieved via the Bookend technique [1,2] using dynamic susceptibility contrast (DSC) MRI and T1 changes in normal white matter (WM) in relation to the changes in the blood pool in a calibration slice, after contrast injection. Quantitative cerebral blood flow (qCBF), quantitative cerebral blood volume (qCBV) and mean transit time (MTT) measu...

متن کامل

SCALE-PWI: A pulse sequence for absolute quantitative cerebral perfusion imaging.

The Bookend technique is a magnetic resonance imaging (MRI) dynamic susceptibility contrast method that provides reliable quantitative measurement of cerebral blood flow (CBF) and cerebral blood volume (CBV). The quantification is patient specific, is derived from a steady-state measurement of CBV, and is obtained from T(1) changes in the white matter and the blood pool after contrast agent inj...

متن کامل

SCALE PWI: A Pulse Sequence for Quantitative Cerebral Perfusion Imaging

INTRODUCTION Quantitative cerebral perfusion is a fundamental physiologic parameter that reflects the severity and progression of a broad range of pathologies including: cancer, stroke, Alzheimer’s Disease, and cerebrovascular occlusive disease. The “Bookend” technique [1,2] allows quantification of cerebral blood flow (CBF) and cerebral blood volume (CBV) with dynamic susceptibility contrast (...

متن کامل

Spin- and Gradient-Echo EPI for Imaging of Brain Perfusion with MRI

INTRODUCTION – A spin and gradient echo (SAGE) EPI sequence that is capable of simultaneously measuring spin(SE) and gradient-echo (GE) perfusion-weighted imaging (PWI) data was previously introduced (1). This sequence was adopted from recent work on PWI by merging multi-GE EPI (2,3) with a combined GE and SE EPI acquisition (4-6). Boxerman et al. (7) found a difference in sensitivity to the un...

متن کامل

Differential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms

Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009