A Reversed Phase High Performance Liquid Chromatographic Method for Determination of Rapamycin
نویسندگان
چکیده
Easily degradating and various isomeric forms of rapamycin (Sirolimus) face the determination of this compound to many challenges. In this study, we developed and validated the isocratic reversed phase high performance liquid chromatographic (RP-HPLC) method for rapamycin. Separation was performed on a C8 column (MZ, 15 × 4.6 mm, 5 μm particle size) using methanol:water (80:20 v/v) as the mobile phase with the flow rate of 1 mL/min. The column temperature was set at 57°C and the detection was carried out at the wavelength of 277 nm. The method was linear over a concentration range of 0.025-2 μg/mL. The coefficient of variation of intra- and inter-day, assessed at three concentration levels of 0.075, 0.3 and 0.900 μg/mL, was less than 2%. Limit of quantification (LOQ) was found 25 ng/mL. The method with high percent recovery and short retention time of rapamycin, was found to be simple, rapid and reproducible.
منابع مشابه
A Reversed Phase High Performance Liquid Chromatographic Method for Determination of Rapamycin
Easily degradating and various isomeric forms of rapamycin (Sirolimus) face the determination of this compound to many challenges. In this study, we developed and validated the isocratic reversed phase high performance liquid chromatographic (RP-HPLC) method for rapamycin. Separation was performed on a C8 column (MZ, 15 × 4.6 mm, 5 µm particle size) using methanol:water (80:20 v/v) as the mobil...
متن کاملA Reversed Phase High Performance Liquid Chromatographic Method for Determination of Rapamycin
Easily degradating and various isomeric forms of rapamycin (Sirolimus) face the determination of this compound to many challenges. In this study, we developed and validated the isocratic reversed phase high performance liquid chromatographic (RP-HPLC) method for rapamycin. Separation was performed on a C8 column (MZ, 15 × 4.6 mm, 5 µm particle size) using methanol:water (80:20 v/v) as the mobil...
متن کاملA High-Performance Liquid Chromatographic Assay for the Determination of Losartan in Plasma
A rapid and sensitive HPLC method was developed for determination of losartan in plasma. Losartan was extracted from plasma by a two-step extraction procedure using chloroform as extracting solvent in acidic medium. HPLC analysis was performed on a cyano reversed-phase column using phosphate buffer (pH 4.3), acetonitrile (750:250, v/v) as mobile phase with a flow rate of 0.9 mL/min. Sodium dicl...
متن کاملSimple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma
A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...
متن کاملSimple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma
A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...
متن کامل