320-row CT renal perfusion imaging in patients with aortic dissection: A preliminary study

نویسندگان

  • Dongting Liu
  • Jiayi Liu
  • Zhaoying Wen
  • Yu Li
  • Zhonghua Sun
  • Qin Xu
  • Zhanming Fan
چکیده

OBJECTIVE To investigate the clinical value of renal perfusion imaging in patients with aortic dissection (AD) using 320-row computed tomography (CT), and to determine the relationship between renal CT perfusion imaging and various factors of aortic dissection. METHODS Forty-three patients with AD who underwent 320-row CT renal perfusion before operation were prospectively enrolled in this study. Diagnosis of AD was confirmed by transthoracic echocardiography. Blood flow (BF) of bilateral renal perfusion was measured and analyzed. CT perfusion imaging signs of AD in relation to the type of AD, number of entry tears and the false lumen thrombus were observed and compared. RESULTS The BF values of patients with type A AD were significantly lower than those of patients with type B AD (P = 0.004). No significant difference was found in the BF between different numbers of intimal tears (P = 0.288), but BF values were significantly higher in cases with a false lumen without thrombus and renal arteries arising from the true lumen than in those with thrombus (P = 0.036). The BF values measured between the true lumen, false lumen and overriding groups were different (P = 0.02), with the true lumen group having the highest. Also, the difference in BF values between true lumen and false lumen groups was statistically significant (P = 0.016), while no statistical significance was found in the other two groups (P > 0.05). The larger the size of intimal entry tears, the greater the BF values (P = 0.044). CONCLUSIONS This study shows a direct correlation between renal CT perfusion changes and AD, with the size, number of intimal tears, different types of AD, different renal artery origins and false lumen thrombosis, significantly affecting the perfusion values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Renal Function in Patients with Unilateral Ureteral Obstruction Using Whole-Organ Perfusion Imaging with 320-Detector Row Computed Tomography

BACKGROUND Obstructed nephropathy is a common complication of several disease processes. Accurate evaluation of the functional status of the obstructed kidney is important to achieve a good outcome. The purpose of this study was to investigate renal cortical and medullary perfusion changes associated with unilateral ureteral obstruction (UUO) using whole-organ perfusion imaging with 320-detecto...

متن کامل

Dose exposure of patients undergoing comprehensive stroke imaging by multidetector-row CT: comparison of 320-detector row and 64-detector row CT scanners.

BACKGROUND AND PURPOSE Recently introduced 320-detector row CT enables whole brain perfusion imaging compared to a limited scanning area in 64-detector row CT. Our aim was to evaluate patient radiation exposure in comprehensive stroke imaging by using multidetector row CT consisting of standard CT of the head, CTA of cerebral and cervical vessels, and CTP. MATERIAL AND METHODS Organ doses wer...

متن کامل

Study of 320-Slice Dynamic Volume CT Perfusion in Different Pathologic Types of Kidney Tumor: Preliminary Results

OBJECTIVE To investigate microcirculatory differences between pathologic types of kidney tumor using 320-slice dynamic volume CT perfusion. METHODS Perfusion imaging with 320-slice dynamic volume CT was prospectively performed in 85 patients with pathologically proven clear cell renal cell carcinoma (RCC) (n = 66), papillary RCC (n = 7), chromophobe RCC (n = 5), angiomyolipoma (AML) with mini...

متن کامل

Computed tomography myocardial perfusion imaging with 320-row detector computed tomography accurately detects myocardial ischemia in patients with obstructive coronary artery disease.

BACKGROUND Computed tomography coronary angiography (CTA) has been shown to be accurate in detecting anatomic coronary arterial obstruction, but is limited for the detection of myocardial ischemia. The primary aim of this study was to assess the accuracy of 320-row computed tomography perfusion imaging (CTP) to detect atherosclerosis causing myocardial ischemia. METHODS AND RESULTS Fifty symp...

متن کامل

Volumetric perfusion CT using prototype 256-detector row CT scanner: preliminary study with healthy porcine model.

This is a preliminary demonstration of volumetric perfusion CT of the brain in domestic pigs by using a prototype 256-detector row CT. Scan range is approximately 100 mm in the craniocaudal direction with 0.5-mm section thickness. The 256-detector row CT is an easily available imaging technique that can provide volumetric cine imaging, CT angiography, and perfusion CT in a wide craniocaudal cov...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017