Hybrid MR-PET - Simultaneous FET-PET and Chemical Shift Imaging

نویسندگان

  • N. J. Shah
  • I. Neuner
  • J. B. Kaffanke
  • C. Filss
  • G. Stoffels
  • H. Herzog
چکیده

Introduction Positron emission tomography is a widely used and established tool for clinical tumour diagnosis and is the gold standard for metabolic imaging. The method complements MR imaging with respect to its metabolic specificity and helps to judge the malignancy and extent of the tumour tissue. Recently, the need to perform two separate scans has been negated through the development of new technologies comprising MR-PET hybrid scanners. These have the advantage of measuring PET and MRI data that are intrinsically co-registered in time and space [1,2,3]. Especially with heterogeneous brain tumours or for the differentiation between active tumour mass and scar tissue after radiation therapy, MR spectroscopy may help to cross-validate and/or extend the PET data. The hybrid approach reduces measurement time and greatly aids patient compliance. This study demonstrates the feasibility of combining anatomical (MP-RAGE) and metabolic-specific information from MR spectroscopy and FET-PET in the investigation of brain tumours in humans utilising a hybrid MR-PET scanner [4]. Methods The whole imaging protocol was performed on a hybrid MR-PET scanner consisting of a 3T MAGNETOM Tim-Trio MR scanner equipped with a BrainPET insert placed at the iso-centre and thereby allowing simultaneous MR and PET acquisition. FET-PET imaging was performed with a tracer injection of 200 MBq of the amino acid O-(2-[F]Fluorethyl)-L-Tyrosin (FET) [5,6]. The BrainPET scan time was 45 min and MRI was performed simultaneously. Anatomical images were acquired with a T1 weighted MP-RAGE sequence in a scan time of 9 min. The matrix size was 256x256x192 to achieve a 1mm isotropic resolution. T1 weighted FLAIR images were acquired for 26 slices. Slice thickness was 5mm and the in-plane resolution was 0.9×0.7mm for an FOV of 220×220mm. MR spectroscopy was performed with a spin-echo CSI sequence with an echo time of 30 ms. A single plane for spectroscopic imaging with a matrix size of 12×12 was carefully placed in the tumour region based on the acquired MPRAGE images. For fat suppression, 8 saturation bands were used and shimming was performed by hand in order to achieve an optimal line width. Image co-registration was carried out with VINCI. Results are presented from a representative patient from our collective. All patients, including the one depicted below (45 yrs, male) gave written, informed consent prior to participation. The whole study was approved by the local ethics commission. Results MR-PET data from a representative patient from our collective of xx patients are shown here. Figure 1) shows transverse slices of the hippocampal / parahippocampal lesion in T1-weigthed MPRAGE (left) and T2-weighted FLAIR (centre) images. The FET-PET shows no enhanced tracer uptake in the regions depicted by MRI that are hypointensive in the MP-RAGE and hyperintensive in the FLAIR images. The spectroscopy signals (Figure 2) reveal an increased relative Myo-Inositol / NAA concentration. This finding indicates an inflammation in the affected tissue [7]. Conclusions The acquisition of multimodal MR-PET data sets can contribute significantly to differential diagnosis of pathological brain lesions. Based on the MR images the pathologic region is evaluated by FET-PET and MR-spectroscopy. In cross validation, both image modalities show that the lesion depicted in the MR images could be due to inflammation rather than being a malignant tumour.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent Advances in PET-MR Hybrid contrast agent

Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...

متن کامل

fMRI investigations on an MR-PET system during simultaneous PET scanning: technical considerations

The new technology of hybrid MR-PET scanners offers great opportunities for the investigation of scientific questions and clinical diagnosis that are related to metabolism as well as function and structure of the brain. Despite the fact that the implementation of a PET ring inside the bore of a modern whole body MR scanner is demanding the benefits in terms of scan time reduction as well as spa...

متن کامل

Trimodal imaging and brain plasticity: MR diffusion tensor imaging supplements simultaneously acquired FET-PET and MP- RAGE of human brain tumour imaging

PET imaging is well established for the diagnosis of brain tumours. Its metabolic specificity delivers valuable information about the malignancy and the extent of tumour tissue. Tumour growth forces the brain to reorganize itself to compensate for the lost areas. It has been shown that DTI is a valuable tool to demonstrate the plasticity of the brain and it therefore offers information about th...

متن کامل

Simultaneous acquisition of dynamic PET-MRI: arterial input function using DSC-MRI and [18F]-FET.

Institute of Neuroscience and Medicine – 4, Forschungszentrum Juelich GmbH, Germany This work focuses on the study of simultaneous dynamic MR-PET acquisition in brain tumour patients. MR-based perfusion-weighted imaging (PWI) and PET [18F]-FET are dynamic methods, which allow to evaluate tumour metabolism in a quantitative way. In both methods, arterial input function (AIF) is necessary for qua...

متن کامل

Dynamic analysis of MR-PET data on brain tumors

Institute of Biophysics and Biomedical Engineering, Faculty of Sciences, University of Lisbon, Portugal The introduction of hybrid MR-PET scanners offers new perspectives to better correlate MR and PET data with respect to time and space domain. In case of brain tumor patients, dynamic susceptibility contrast (DSC)-MRI is often used to measure perfusion levels of brain, while dynamic [F]-fluoro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010