Anthropomorphic breast phantoms for quality assurance and dose verification

نویسندگان

  • José A. Bencomo
  • Connel Chu
  • Victor M. Tello
  • Sang Hyun Cho
  • Geoffrey S. Ibbott
چکیده

An evaluation of two anthropomorphic breast phantoms, which have been designed for quality assurance and dose verification of radiotherapy treatment of breast cancer patients, is presented. These phantoms are identical in terms of their dimensions and shape, and composed of several layers of either Plastic Water or tissue-equivalent material. Both water- and tissue-equivalent phantoms include lung- and rib-equivalent components. The phantoms simulate large, medium and small breasts. The value of the phantoms as breast treatment quality assurance tools was assessed by dose measurements with ionization chamber and thermoluminescence dosimeters (TLD), at different points inside the phantom. Measurements were made by irradiating the phantoms under conditions representing the different treatment techniques, found by the Radiological Physics Center (RPC) during its dosimetry quality audits. Most irradiations were performed with the water-equivalent breast phantom. One experiment was performed under consistent irradiation conditions to compare the tissue-equivalent phantom with the water-equivalent phantom. Measurements were compared with the dose estimated by the RPC's manual calculations used to check clinical charts of patients entered in a National Surgical Adjuvant Breast and Bowel Project (NSABP) protocol. Measurements were also compared with isodose distributions generated by a commercial radiation treatment planning (RTP) system. In the homogeneous three-dimensional (3-D) phantom, fairly good agreement (within 5%) was observed at the NSABP dose prescription point between measurements and 2-D dose estimation by manual calculations. At the same dose prescription point, but located in the heterogeneous 3-D phantom, agreement between measurements and a 3-D RTP system was within about 3%. Manual calculation resulted in overestimation of up to 6%. The general agreement between the TLD measurements and the 2-D RTP values was within 3% at various off-axis points, with the exception of a few points far off-axis, near the high-dose gradient region at the surface of the phantom.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional gel dosimetry for dose volume histogram verification in compensator-based IMRT

Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...

متن کامل

Design of an Anthropomorphic Intensity Modulated Radiation Therapy Quality Assurance Phantom

The dynamic nature of IMRT delivery poses unique problems relating to the accurate and reproducible quality assurance of dose delivery. The usefulness of point detectors is limited to static fields and regions within low dose-gradients for treatment verification. However, dose distributions generated in intensity modulated radiation therapy (IMRT) often have complex shapes with high dose gradie...

متن کامل

Dosimetry for audit and clinical trials: challenges and requirements

Many important dosimetry audit networks for radiotherapy have their roots in clinical trial quality assurance (QA). In both scenarios it is essential to test two issues: does the treatment plan conform with the clinical requirements and is the plan a reasonable representation of what is actually delivered to a patient throughout their course of treatment. Part of a sound quality program would b...

متن کامل

Point Dose Measurement for Verification of Treatment Planning System using an Indigenous Heterogeneous Pelvis Phantom for Clarkson, Convolution, Superposition, and Fast Superposition Algorithms

Background: Nowadays, advanced radiotherapy equipment includes algorithms to calculate dose. The verification of the calculated doses is important to achieve accurate results. Mostly homogeneous dosimetric phantoms are available commercially which do not mimic the actual patient anatomy; therefore, an indigenous heterogeneous pelvic phantom mimicking actual human pelvic region has been used to ...

متن کامل

A Specific Patient Quality Assurance (PSQA) procedure for a Co-60 source based High Dose Rate Brachytherapy

Introduction: In radiation therapy, accurate dose determination and precise dose delivery to the tumor are directly associated with better treatment outcomes in terms of higher tumor control and lower post radiation therapy complications. The current study aims the development and clinical application of the Patient Specific Quality Assurance (PSQA) procedures for nasopharyngea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2004