A Three-dimensional Tagged Magnetic Resonance Imaging Study
نویسندگان
چکیده
Background Regional performance of the hypertrophied left ventricle (LV) in hypertrophic cardiomyopathy (HCM) is still incompletely characterized with studies variably reporting that the hypertrophied myocardium is hypokinetic, akinetic, or has normal function. Different imaging modalities (M-mode or two-dimensional echocardiography) and methods of analysis (fixed or floating frame of reference for wall motion analysis) yield different results. We assessed regional function in terms of systolic wall thickening and shortening and related these parameters to end-diastolic thickness using tagged magnetic resonance imaging and the three-dimensional volume-element approach. Methods and Results In 17 patients with HCM and 6 healthy volunteers, four parallel short-axis images with 12 radial tags and two mutually orthogonal long-axis images with four parallel tags were obtained at end diastole and end systole. After the LV endocardial and epicardial borders were traced, threedimensional volume elements were constructed by connecting two matched planar segments in two adjacent short-axis image planes, accounting for translation, twist, and long-axis shortening. A total of 72 such volume elements encompassed the entire LV. From each of these elements, end-diastolic thickness and systolic function (fractional thickening and circumferential shortening) were calculated. The average end-diastolic thickness was 15.8±4.2 mm in patients with HCM, which was significantly greater than that in healthy subjects (8.6±2.1 mm, P<.001). Fractional thickening was significantly less in patients with HCM than in healthy subjects (0.31±0.22 versus 0.56±0.23, P<.001). There was a highly significant inverse correlation between fractional thickening and end-diastolic thickness that was independent of the type of hypertrophy or age group. Similar inverse relations were observed between circumferential shortening and end-diastolic wall thickness. Conclusions The myocardium in patients with HCM is heterogeneously thickened and the fractional thickening and circumferential shortening of the abnormally thickened myocardium are reduced compared with healthy subjects. The decrease in fractional thickening and shortening is inversely related to the local thickness. (Circulation. 1994;90:1200-1209.)
منابع مشابه
Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...
متن کاملFabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...
متن کاملApplication of computed tomography and magnetic resonance imaging fusion images for delineating gross tumor volume in three-dimensional conformal radiotherapy of nasopharyngeal carcinoma
Background: To evaluate computed tomography (CT) and magnetic resonance imaging (MRI) fusion images for delineating gross tumor volume (GTV) in three-dimensional conformal radiotherapy (3D-CRT) of nasophanrygeal carcinoma (NPC), and compare treatment outcomes between CT- and CT+MRI-based targets. Materials and Methods: A total of 120 NPC patients treated with 3D-CRT were included, in which, 60 ...
متن کاملAutomatic 3D tracking of cardiac material markers using slice-following and harmonic-phase MRI.
A method to track a grid of cardiac material points in three dimensions using slice-following (SF) tagged magnetic resonance imaging (MRI) and harmonic-phase MRI is presented. A three-dimensional grid of material points on the lines of intersections of short-axis (SA) and long-axis (LA) planes is automatically tracked by combining two-dimensional pathlines that are computed on both SA and LA im...
متن کاملDesign and Fabrication of a Four-Dimensional Respiratory Phantom for Studying Tumor Movement in Radiotherapy with Magnetic Resonance Imaging
Introduction: In radiation therapy, determining the location of the tumor accurately during irradiation is one of the most important requirements. However, lung tumors are not fixed in a single location and move during irradiation due to respiratory motion. Due to limitations in assessing such movements, using a lung phantom can be useful and operational for their fast, easy an...
متن کاملO-19: A Comparison of Pelvic Magnetic Resonance Imaging, Trans-Vaginal and Trans-Rectal Sonography with Laparoscopic Findings in The Diagnosis of Deep Infiltrating Endometriosis
Background The performance of TVS, TRS and MRI for the diagnosis of DIE have been separately reported in earlier studies. However, the three methods have not been concurrently compared in terms of their overall performance and classified results as per different anatomical locations of DIE lesions in a large study population. This study was an attempt to compare pelvic magnetic resonance imagin...
متن کامل