[Sentinel node detection of patients with breast cancer by radionuclide method: consideration of radiation safety].
نویسندگان
چکیده
Sentinel node was detected by 99mTc labeled nanocolloid in five patients with breast cancer. Surgery of breast cancer was done at 16 hours after the administration of 74 MBq of 99mTc labeled nanocolloid. Sentinel node was searched by scintigraphy prior to surgery and by gamma-probe during surgery. Radioactivity of injected site, sentinel nodes, blood contaminated gauze, and other garbage was measured by GM detector. Radiation to medical staffs was monitored by a pocket radiation detector and film batches. Sentinel nodes were successfully detected both by scintigraphy and gamma-detector. More than 70% of radioactivity remained in the administered site at 16 hours. Small amount of radioactivity was detectable in the sentinel node. Almost no radioactivity was detectable in blood-contaminated gauze and other garbage. Radiation dose to the main surgeon was 4 to 6 microSv per surgery by a pocket radiation detector. Radiation dose to the assistant surgeon was 2 microSv per surgery. Radiation dose by labeling or injection was 0 to 1 microSv per procedure. No detectable radiation was measured by film batches. It is concluded that the detection of sentinel node by 99mTc labeled nanocolloid is a safe procedure from the point of radiation safety consideration.
منابع مشابه
Sentinel node mapping for early breast cancer patients using 99mTc-phytate: Single center experience on 165 patients
Introduction: Several radiotracers are being used for sentinel node mapping in patients with breast cancer. In the current study, we reported our experience with 99m-Tc Phytate for sentinel node mapping in Mashhad University of Medical Sciences. Methods: All breast cancer patients who underwent sentinel node mapping using 99m-Tc Phytate were included. All patients received intradermal peri-are...
متن کاملSentinel node detection failure due to defective labeling and large particle size of Tc-99m antimony sulfide colloid
Introduction: Many radiotracers have been used for sentinel node mapping with acceptable results. The main difference between these radiotracers is the particle size. In the current study, we reported defective labeling of Tc-99m antimony sulfide colloid which resulted in large particle size. Methods: Tc-99m-Antimony sulfide colloid was used for axillary sentinel n...
متن کاملStandardization of whole breast radiotherapy is required for safe omission of axillary lymph node dissection in breast cancer patients
Background: The purpose of this study was to assess the dose distribution and coverage of level Ⅰ-Ⅱ axillary lymph nodes during whole breast tangential field radiotherapy (RT) after breast-conserving surgery in patients with breast cancer. Materials and Methods: The level Ⅰ-Ⅱ axillary lymph node volumes were retrospectively contoured by a single radiation oncologist based on computed tomography...
متن کاملTime frame of sentinel node visualization in early breast cancer patients using intradermal injection of Tc-99m phytate: Imaging beyond 45 minutes does not yield more information
Introduction: One of the major problems of lymphoscintigraphy is the time of patient presence in the nuclear medicine wards. The operating room schedule can be compromised if the patients stay longer than usual in the nuclear medicine departments. However, too early imaging can be falsely negative for sentinel node visualization and delayed imaging may be required. The aim of t...
متن کاملDynamic lymphoscintigraphy in breast cancer patients: feasibility and added value
Introduction: Lymphoscintigraphy is imaging of the lymphatic system and has been integrated into the sentinel node mapping procedures. Lymphoscintigraphy usually encompasses early or delayed static images. However, immediate dynamic imaging of the lymphatic basins and tumors has also been used as an adjunct lymphoscintigraphy imaging. The aim of this study was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Kaku igaku. The Japanese journal of nuclear medicine
دوره 38 1 شماره
صفحات -
تاریخ انتشار 2001