Continuous subcutaneous glucose monitoring: good enough to use in glucose regulation protocols?

نویسندگان

  • Jack JM Ligtenberg
  • Margo E de Plaa
  • Jan G Zijlstra
چکیده

cial in subgroups of inten sive care unit (ICU) patients, but may harm other sub groups. Th is harm may be due to hypoglycemic events. In avoiding hypoglycemia, an accurate bedside glucometry method is essential [1]. Bridges and colleagues therefore evaluated the accuracy of a continuous subcutaneous glucose monitoring system (CGMS) in critically ill children, and concluded that the system proves highly accurate [2]. We have a problem with this resolute conclusion. Th ey report a Pearson’s correlation coeffi cient of 0.68, which is quite low. Vlkova and colleagues even conclude that, based on a correlation coeffi cient of 0.69 comparing subcutaneous glucose values and laboratory blood glucose values in 15 patients, subcutaneous devices should not be used in critically ill patients [3]. We found a correlation coeffi cient of 0.87 in evaluating the same CGMS in 60 critically ill patients, but were concerned with the inaccuracy in the low glucose zone: we found a diff erence of nearly 4 mmol/l (reference blood glucose 2.8 mmol/l versus subcutaneous sensor 6.5 mmol/l) in one patient [4]. Bridges and colleagues report 142 subcutaneous glucose readings <2.2 mmol/l that were falsely low, checked against blood glucose values. Th e Clarke error grid is a better way to evaluate the accuracy of a CGMS than Pearson’s correlation coeffi cient. In most published studies, the deviation of subcuta neous measurements stays in the (wide) clinically accep table zones of the Clarke error grid. Th ese deviations of the CGMS system, however, when used in a tight glucose regulation protocol – and adjusting the insulin dose based on the subcutaneous readings – could have severe consequences in the individual patient, if the deviations result in an unjust rise in insulin dose. Since computerized protocols based on arterial blood samples give excellent glucose regulation with a negligible chance of hypoglycemic events [5], we decided to continue using this computerized protocol to avoid treatment-related morbidity. Subcutaneous CGMS seems not good enough in aiming for tight glucose regulation in the ICU. Intravascular CGMS, used in a closed feedback loop with insulin infusion, is promising, but has not yet been evaluated in clinical studies in critically ill patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Editorial: symposium on algorithms for continuous glucose monitoring and control.

1 S YSTEMS AND CONTROL THEORY is the basis for algorithms embedded in many of the products (both high and low " tech ") that we use in our daily lives. While consumers appreciate the relative compactness of CD and DVD players and microdrives, for example, and value the manufacturing technology involved in minia-turization, they probably do not think much about the mathematical algorithms that e...

متن کامل

Glucose control in the intensive care unit by use of continuous glucose monitoring: what level of measurement error is acceptable?

BACKGROUND Accuracy and frequency of glucose measurement is essential to achieve safe and efficacious glucose control in the intensive care unit. Emerging continuous glucose monitors provide frequent measurements, trending information, and alarms. The objective of this study was to establish the level of accuracy of continuous glucose monitoring (CGM) associated with safe and efficacious glucos...

متن کامل

Glucose sensing issues for the artificial pancreas.

The first retrospective continuous glucose monitor entered the market in 1999. Now that this tool gives online data, the question arises whether it is ready to be incorporated into a closed-loop system. The author discusses the following questions: (1) Is the accuracy of current continuous glucose monitoring (CGM) systems good enough for use in a prototype artificial pancreas system?; (2) How d...

متن کامل

Use of long-term microdialysis subcutaneous glucose monitoring in the management of neonatal diabetes. A first case report.

In neonatal diabetes mellitus (NDM), a rare genetic disorder, insulin therapy is required but the management is difficult. Frequent blood glucose determinations are necessary in most cases. Microdialysis subcutaneous glucose monitoring (MSGM) is feasible in neonates and has been proposed to reduce painful blood sampling and blood loss. We have applied long-term MSGM to a small-for-date female n...

متن کامل

Comparing Effects of Continuous Insulin Infusion with or without Subcutaneous Glargine Insulin on Glycemic Control in Diabetic Patients Undergoing Coronary Artery Bypass Graft (CABG)

OBJECTIVE: Hyperglycemia is associated with increased morbidity and mortality in diabetic patients following coronary artery bypass grafting. Tight glycemic control in perioperative period can reduce these events. The goal of this study was to determine whether combination of continuous infusion and subcutaneous glargine as a basal insulin could improve glycemic control. MATERIAL AND METHODS:...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2011