Modelling and control of potable water chlorination.

نویسندگان

  • A Pastre
  • M Mulholland
  • C J Brouckaert
  • C A Buckler
  • M V Le Lann
  • M Roustan
  • D Naidoo
  • V Mabeer
چکیده

The Umgeni Water Wiggins water treatment plant feeds the southern areas of Durban in South Africa and has a maximum treatment capacity of about 350 Ml/d. Two interconnected reservoirs at this facility hold treated water before it enters the distribution network. Because of the variable demand, the reservoir levels and residence times undergo considerable variation. This has a strong influence on the free chlorine concentration in the water leaving the reservoir, which should be 0.8 to 1.2 mg/l, to ensure an adequate disinfection potential within the network. This paper describes a model which accounts for the observed variations of chlorine concentration, and will form the basis of a predictive controller for the chlorine concentration in the outlet.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modelling of Micropollutant Removal by Ozonation and Chlorination in Potable Water Treatment

In regards of increasingly stringent rules on toxicity, prediction engines for potable water treatment have become a necessity. This particularly applies to oxidation steps, where micropollutants should be removed and where potentially harmful by-products may be formed, and has therefore lead to the building up of a new simulator for both chlorination and ozonation. This first report aims at gi...

متن کامل

A novel technology to improve drinking water quality: a microbiological evaluation of in-home flocculation and chlorination in rural Guatemala.

An estimated 1 billion persons in low-income countries do not have access to improved drinking water. Chlorine, a useful water treatment agent, is less effective in turbid water, and lacks a visible effect, limiting its acceptability. A product incorporating precipitation, coagulation, flocculation, and chlorination technology (combined product) to reduce microbial, organic and heavy metal cont...

متن کامل

Assessment of the risk of infection by Cryptosporidium and Giardia in non-potable reclaimed water.

Quantitative risk assessment for Cryptosporidium oocysts and Giardia cysts was performed to determine the public health significance of non-potable use of tertiary treated reclaimed water. Seven reclaimed water treatment plants in the southwestern United States participated in this study. The average public exposure to oocysts and cysts was estimated, based on concentrations, recovery efficienc...

متن کامل

بررسی عوامل مرتبط در استفاده از کلر 1% در خانوارهای تحت پوشش خانه های بهداشت استان سیستان و بلوچستان، 1380

According to the reports of world health organization (WHO), 80 percent of human diseases are due to contaminated water either for drinking or sanitation. International water sanitation program says that 50 percent of people across the world have no access to healthy water and 75 percent of the third world population do not have water for sanitation. The present semi experimental study aims at...

متن کامل

Uses of inorganic hypochlorite (bleach) in health-care facilities.

Hypochlorite has been used as a disinfectant for more than 100 years. It has many of the properties of an ideal disinfectant, including a broad antimicrobial activity, rapid bactericidal action, reasonable persistence in treated potable water, ease of use, solubility in water, relative stability, relative nontoxicity at use concentrations, no poisonous residuals, no color, no staining, and low ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Water science and technology : a journal of the International Association on Water Pollution Research

دوره 46 9  شماره 

صفحات  -

تاریخ انتشار 2002