Human Brain Imaging at 9.4 Tesla Using a Combination of Traveling Wave Excitation with a 15-channel Receive-only Array

نویسندگان

  • J. O. Hoffmann
  • G. Shajan
  • R. Pohmann
چکیده

Introduction The combination of a circularly polarized (CP) volume coil for spin excitation with a multi-channel receive-only array is a successful setup for routine human brain imaging at 7 Tesla. For reception, the use of multiple surface coils is important for a high SNR and for the utilization of parallel imaging techniques. For transmission, the main strength of the CP coil is the reasonable B1 homogeneity over a large FOV in unison with simple usage, which is in contrast with more sophisticated static or tailored RF shimming techniques using multichannel transmit coils. At 9.4 Tesla, however, the even shorter RF wavelength in tissue causes the B1 field to be unacceptably inhomogeneous, especially in the ventral parts of the brain. In addition, the field-of-view of coils that are based on half-lambda resonators further decreases. Therefore, a substitute for the CP coil with a more uniform B1 field pattern over a large FOV is desirable. Traveling wave imaging [1] using a Tx/Rx patch antenna has the potential to provide a more homogeneous spin excitation over larger regions [2, 3], but in turn suffers from poor sensitivity. Therefore, we tested the combination of traveling wave excitation with a 15-channel receive-only array and show initial results utilizing this setup for human brain imaging at 9.4 Tesla.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A 3-Port Traveling-Wave Antenna in Combination with TIAMO for the Acquisition of Void-Free Brain Images at 9.4 Tesla

Background: The original traveling-wave approach uses a remotely placed antenna to stimulate the propagation of two TE11 waveguide modes in circular polarization (CP) within a human 7 T scanner. While this approach enables large field-of-view imaging and provides free space around the subject, one major drawback is the small number of transmit/receive sensitivities (i.e. the two TE11 modes), wh...

متن کامل

A Specialized Multi-Transmit Head Coil for High Resolution fMRI of the Human Visual Cortex at 7T

PURPOSE To design, construct and validate radiofrequency (RF) transmit and receive phased array coils for high-resolution visual cortex imaging at 7 Tesla. METHODS A 4 channel transmit and 16 channel receive array was constructed on a conformal polycarbonate former. Transmit field efficiency and homogeneity were simulated and validated, along with the Specific Absorption Rate, using [Formula:...

متن کامل

96-Channel receive-only head coil for 3 Tesla: design optimization and evaluation.

The benefits and challenges of highly parallel array coils for head imaging were investigated through the development of a 3T receive-only phased-array head coil with 96 receive elements constructed on a close-fitting helmet-shaped former. We evaluated several designs for the coil elements and matching circuitry, with particular attention to sources of signal-to-noise ratio (SNR) loss, includin...

متن کامل

High Spatial Resolution Proton-Echo-Planar-Spectroscopic-Imaging (PEPSI) in Human Brain at 3 Tesla using 32-Channel RF Coil Array

15 mm PEPSI slice) and metabolic images of mI, Cho, Cr+PCr, Glu+Gln, NAA+NAAG and macromolecules at 0.9 ppm (MM09) measured with 0.25 cc spatial resolution, (left) before and (right) after partial volume and relaxation correction. Cho, Cr+PCr and Glu+Gln maps show strong GM/WM contrast and considerable anatomical detail, including sulcal structure (see red and yellow arrows). Fig.1:Selected cen...

متن کامل

Traveling Wave Imaging of the Human Head at 7 Tesla: Assessment of SNR, Homogeneity and B1+ Efficiency

Introduction: The traveling wave concept for 7T MR imaging was first demonstrated by Brunner et al [1]. In the most common RF transmit coil designs, a quadrature RF field is created within a cylindrical volume in the near-field regime. In contrast, the traveling wave approach creates a traveling wave mode down the entire bore of the scanner. This has the potential to provide more uniform excita...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010