In vitro human monocyte response to wear particles of titanium alloy containing vanadium or niobium.

نویسندگان

  • S D Rogers
  • D W Howie
  • S E Graves
  • M J Pearcy
  • D R Haynes
چکیده

Our aim was to determine whether in vitro studies would detect differences in the cellular response to wear particles of two titanium alloys commonly used in the manufacture of joint replacement prostheses. Particles were of the order of 1 microm in diameter representative of those found adjacent to failed prostheses. Exposure of human monocytes to titanium 6-aluminium 4- vanadium (TiAlV) at concentrations of 4 x 10(7) particles/ml produced a mean prostaglandin E2 release of 2627.6 pM; this was significantly higher than the 317.4 pM induced by titanium 6-aluminium 7-niobium alloy (TiAlNb) particles (p = 0.006). Commercially-pure titanium particles induced a release of 347.8 pM. In addition, TiAlV stimulated significantly more release of the other cell mediators, interleukin-1, tumour necrosis factor and interleukin-6. At lower concentrations of particles there was less mediator release and less obvious differences between materials. None of the materials caused significant toxicity. The levels of inflammatory mediators released by phagocytic cells in response to wear particles may influence the amount of periprosthetic bone loss. Our findings have shown that in vitro studies can detect differences in cellular response induced by particles of similar titanium alloys in common clinical use, although in vivo studies have shown little difference. While in vitro studies should not be used as the only form of assessment, they must be considered when assessing the relative biocompatibility of different implant materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Induction of macrophage C-C chemokine expression by titanium alloy and bone cement particles.

Particulate wear debris is associated with periprosthetic inflammation and loosening in total joint arthroplasty. We tested the effects of titanium alloy (Ti-alloy) and PMMA particles on monocyte/macrophage expression of the C-C chemokines, monocyte chemoattractant protein-1 (MCP-1), monocyte inflammatory protein-1 alpha (MIP-1alpha), and regulated upon activation normal T expressed and secrete...

متن کامل

Evaluation of Plasma Nitriding Efficiency of Titanium Alloys for Medical Applications

Wide use of titanium alloys results from their unique physical and chemical properties 1 . Combination of low density and improved corrosion resistance with good plasticity and mechanical properties determines application of titanium alloys in such industries as aviation, automotive, power and shipbuilding industries or architecture as well as medicine and sports equipment. Despite numerous adv...

متن کامل

The differences in toxicity and release of bone-resorbing mediators induced by titanium and cobalt-chromium-alloy wear particles.

We investigated the relationship between the toxic effects of metal wear particles and their ability to stimulate the release of inflammatory mediators implicated in bone resorption. In vitro studies were carried out with use of rat peritoneal macrophages, which were exposed to either cobalt-chromium-alloy or titanium-aluminum-vanadium particles, milled from the metal components of hip prosthes...

متن کامل

Production of Dispersed Ceramic Nano-Particles in Al Alloy Using Friction Stir Processing

In this research, surface composite layers containing nano sized TiB2, Al2O3-TiB2, ZrO2 and CNT particles have been fabricated on Aluminum alloy substrates by friction stir processing. The effects of different processing variables such as number of passes and strengthening particle distribution, hardness, and wear properties of surface nano...

متن کامل

Biological Response to Particulate Debris: In Vitro and In Vivo Studies

In this study, we compared the results of a human monocyte in vitro model and a canine in vivo model, to evaluate the response to different types of particulate wear debris. Both the in vitro and in vivo studies demonstrated that titanium-6 aluminum-4 vanadium (TiAIV), ultrahigh molecular weight polyethylene (UHMWPE) and other particulate wear debris are stimulatory to macrophages and elicit re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 79 2  شماره 

صفحات  -

تاریخ انتشار 1997