Performance of a reservoir nasal cannula (Oxymizer) during sleep in hypoxemic patients with COPD.

نویسندگان

  • E M Hagarty
  • M S Skorodin
  • W M Stiers
  • M B Mamdani
  • J A Jessen
  • E C Belingon
چکیده

STUDY OBJECTIVE To determine whether a reservoir nasal cannula (RNC) (Oxymizer) provides an arterial hemoglobin oxygen saturation as measured by pulse oximetry (SpO2) equivalent to that provided by the standard nasal cannula (SNC) during sleep in hypoxemic patients with COPD while reducing oxygen flow requirement and cost. DESIGN The study took place in a sleep laboratory for three nights, with the first night for acclimatization to the new sleeping environment. In a repeated-measures design, on the second and third nights, subjects used the SNC for one night and the RNC on another night. The order in which they received the two devices was counterbalanced. SUBJECTS The subjects were patients with COPD who had a stable PaO2 of 55 mm Hg or less or had a value of 56 to 59 mm Hg with evidence of cor pulmonale or polycythemia (or both) and an FEV1/FVC of less than 70 percent. INTERVENTIONS A pulse oximeter was used to measure SpO2. An arterial blood gas measurement was taken on each night while the patients with COPD were receiving oxygen therapy via the assigned device. An EEG machine was used to record measurements of electro-oculography, chin electromyography (EMG), anterior tibialis EMG and EEG. MEASUREMENTS AND MAIN RESULTS There was a statistically significant difference between mean SpO2 during sleep (RNC, 91 percent; SNC, 93 percent; F = 7.89; p = 0.01). Nocturnal SpO2 was less than 90 percent for 24.2 percent of the time with the RNC and for 17.5 percent of the time with the SNC (F = 5.41; p = 0.03), but there was no significant difference in the amount of time that SpO2 was less than 85 percent. Compared to the SNC, in 4 of 26 patients with COPD, the RNC performed better; in 12 patients with COPD, the RNC performed the same, and in 10 patients with COPD the RNC performed worse during sleep. Sleep parameters were not significantly different between the two devices. CONCLUSIONS The difference of 2 percent in mean SpO2 is within the range of SpO2 measurement error. Therefore, the two devices are equally effective when the sample is considered as a whole. Nighttime oximetry is necessary prior to prescription, since nighttime efficacy of the RNC cannot be predicted on the basis of daytime pulse oximetry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Benefits of an oxygen reservoir cannula versus a conventional nasal cannula during exercise in hypoxemic COPD patients: a crossover trial.

BACKGROUND The Oxymizer® is a special nasal cannula that provides a higher luminal diameter in combination with an incorporated oxygen (O2) reservoir. It is assumed that a higher O2 concentration can be delivered breath by breath in order to increase oxygenation. OBJECTIVE We aimed to investigate the effects of the Oxymizer on endurance time in comparison to a conventional nasal cannula (CNC)...

متن کامل

A conservation device for oxygen therapy in COPD.

Patients with hypoxaemia secondary to chronic obstructive pulmonary disease (COPD) are frequently prescribed oxygen therapy for short- and long-term domiciliary use. Oxygen administered via nasal cannulae incorporating a small collapsible reservoir ("Oxymizer", Chad Therapeutics Inc., CA, USA) improves transcutaneous oxygen tensions in the short-term when compared to standard nasal cannulae. Th...

متن کامل

Conservation of oxygen supply using a reservoir nasal cannula in hypoxemic patients at rest and during exercise.

A reservoir nasal cannula which stores oxygen during exhalation and delivers it as a bolus during inhalation has been reported to conserve oxygen delivery in patients with chronic obstructive pulmonary disease (COPD) at rest. We compared the effects upon arterial oxygen saturation (SaO2) of the reservoir cannula and a standard nasal cannula in hypoxemic obstructed and restricted patients at res...

متن کامل

A new pendant oxygen-conserving cannula which allows pursed lips breathing.

Multiple benefits of oxygen therapy for hypoxemic patients with chronic lung disease are well established. Steady flow oxygen therapy is inefficient, wasteful and has a high cost. The Oxymizer pendant improves efficiency of oxygen delivery compared with SF. However, the device requires that the patient inhale and exhale nasally to maximize its oxygen-saving properties. When patients do PLB they...

متن کامل

Performance of a demand oxygen saver system during rest, exercise, and sleep in hypoxemic patients.

Demand oxygen systems have been shown to be effective in treating hypoxemia during seated rest and during exercise, but the performance of these systems during sleep has not been previously studied. We compared the efficacy of a new demand oxygen saver system with that of continuous flow nasal oxygen during the usual activities of daily life including sleep, seated rest, and exercise. Six hypox...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 103 4  شماره 

صفحات  -