The Measurement of Lymphocyte Volume : Importance of Reference Particle Deformability and Counting Solution
نویسنده
چکیده
We have determined the influence of reference particle deformability and suspending buffer tonicity on the measurement of lymphocyte volume by an electronic particle volume analyzer. When the volume analyzer was standardized with latex spherules having a shape factor (f.) of 1 .5. red cell volume was 96 cu m and lymphocyte volume was 289 cu m. The red cell volume corresponded closely to the true red cell volume; the true lymphocyte volume. however. was 21 8 cu sm when measured by the lymphocytocrit/lymphocyte count and 203 cu m by wet lymphocyte weight and density (mean 21 0 cu im). The difference between the electronic volume ( V.) of 289 cu Mm and true lymphocyte volume of 21 0 cu tm was due to the influence of lymphocyte deformability (shape factor) as
منابع مشابه
The measurement of lymphocyte volume: importance of reference particle deformability and counting solution tonicity.
We have determined the influence of reference particle deformability and suspending buffer tonicity on the measurement of lymphocyte volume by an electronic particle volume analyzer. When the volume analyzer was standardized with latex spherules having a shape factor (fe) of 1.5, red cell volume was 96 cu micron and lymphocyte volume was 289 cu micron. The red cell volume corresponded closely t...
متن کاملOn the Dependence of Soot Formation and Combustion on Swirling Combustion Furnaces: Measurement and Simulation
Soot concentration distribution is investigated both numerically and experimentally in methane-air diffusion flame. The experimental work is conducted with a cylindrical swirl stabilized combustor. Filter paper technique is used to measure soot volume fraction inside the combustor. The numerical simulation is based on the solution of the fully-coupled conservation equations for swirling turbule...
متن کاملA method for bubble volume measurement under constant flow conditions in gas–liquid two-phase flow
Measuring the volume of a bubble, especially at its detachment, is a basic subject in gas-liquid two-phase flow research. A new indirect method for this measurement under constant flow conditions is presented. An electronic device is designed and constructed based on laser beam intensity. This device calculates the frequency of the bubble formation by measuring the total time of the formation p...
متن کاملReference values of T lymphocyte subsets among health adults in Inner Mongolia Region.
Estimation of T-lymphocyte subsets continues to be an important aspect for monitoring HIV disease progression and response to antiretroviral therapy. Most of the diagnostic laboratories often rely on studies from western for CD4+T-lymphocyte reference values, which could, often be unreliable for usage in local settings. To establish the normal reference values of T lymphocyte subsets from healt...
متن کاملFabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...
متن کامل