Magnetostrictive Microcantilever as an Advanced Transducer for Biosensors

نویسندگان

  • Liling Fu
  • Suiqiong Li
  • Kewei Zhang
  • I-Hsuan Chen
  • Valery. A. Petrenko
  • Zhongyang Cheng
چکیده

The magnetostrictive microcantilever (MSMC) as a high-performance transducer was introduced for the development of biosensors. The principle and characterization of MSMC are presented. The MSMC is wireless and can be easily actuated and sensed using magnetic field/signal. More importantly, the MSMC exhibits a high Q value and works well in liquid. The resonance behavior of MSMC is characterized in air at different pressures and in different liquids, respectively. It is found that the Q value of the MSMC in water reaches about 40. Although the density and viscosity of the surrounding media affect the resonance frequency and the Q value of MSMC, the density has a stronger influence on the resonance frequency and the viscosity has a stronger influence on the Q value, which result in that, for MSMC in air at pressure of less than 100 Pa, the resonance frequency of MSMC is almost independent of the pressure, while the Q value increases with decreasing pressure. MSMC array was developed and characterized. It is experimentally demonstrated that the characterization of an MSMC array is as simple as the characterization of a single MSMC. A filamentous phage against Salmonella typhimurium was utilized as bio-recognition unit to develop an MSMC based biosensor. The detection of S. typhimurium in water demonstrated that the MSMC works well in liquid.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On magnetostrictive materials and their use in adaptive structures

Magnetostrictive materials are routinely employed as actuator and sensor elements in a wide variety of noise and vibration control problems. In infrastructural applications, other technologies such as hydraulic actuation, piezoelectric materials and more recently, magnetorheological fluids, are being favored for actuation and sensing purposes. These technologies have reached a degree of technic...

متن کامل

Nanobiosensors and fluorescence based biosensors: An overview

A biosensor can sense biological elements after interaction with the recognition element. The signal produced due to interaction of the analyte with its biochemical element is transduced by a transducer and detected by appropriate modes. The miniaturization of these biosensors at the nano level using nanostructures as a platform for sensing the analyte or its detection is called a nanobiosensor...

متن کامل

Nanobiosensors and fluorescence based biosensors: An overview

A biosensor can sense biological elements after interaction with the recognition element. The signal produced due to interaction of the analyte with its biochemical element is transduced by a transducer and detected by appropriate modes. The miniaturization of these biosensors at the nano level using nanostructures as a platform for sensing the analyte or its detection is called a nanobiosensor...

متن کامل

Improved surface modification approach for micromechanical biosensors.

We have investigated the sensing performance of protein-based microcantilever biosensors prepared from multiple surface conjugation chemistries. The 11-mercaptoundecanoic acid monolayers were prepared according to both traditional and modified processes. In three protein-based biosensors, the modified process improved microcantilever sensing performance by increasing the bending amplitude, a cr...

متن کامل

One-dimensional Analytical Constant Parameter Linear Electromagnetic-magnetomechanical Models of a Cylindrical Magnetostrictive (terfenol-d) Transducer

A method is presented for including motional and eddy current effects when analytically modeling electrical impedance functions of cylindrical magnetostrictive transducers. To approximate eddy current effects, one-dimensional analytical constant parameter linear electromagnetic models of a cylindrical magnetostrictive transducer are developed. Maxwell's equations are solved for the magnetic fie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2007