Elevation Correction Factors K)r E-perm(r) Radon Monitors

نویسنده

  • R. Stief
چکیده

E-PERM(R) radon monitors are based on the principle of electret ion chambers and these are usually calibrated in a standard radon chamber located at sea level. Corrections are needed if these are used in elevations other than sea level. These were experimentally determined for three models of commercially available electret ion chambers (E-PERMS(R)) as functions of elevation above sea level. . These constitute a slowly varying minor corrections. 1 E-PERM(R) is a registered trademark of the product patented and manufactured by Rad Elec Inc., Frederick, MD 21701 USA 2 Modified version of this paper is in the process of publication in Health Physics Journal (1992).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration of Electret-Based Integral Radon Monitors Using NIST Polyethylene-Encapsulated 226Ra/222Rn Emanation (PERE) Standards

The recently developed 222Rn emanation standards that are based on polyethylene-encapsulated 226Ra solutions were employed for a first field-measurement application test to demonstrate their efficacy in calibrating passive integral radon monitors. The performance of the capsules was evaluated with respect to the calibration needs of electret ionization chambers (E-PERM®, Rad Elec Inc.). The enc...

متن کامل

Electret ion chamber-based passive radon-thoron discriminative monitors.

Electret ion chambers (EICs), commercially available under brand name E-PERM(®), are widely used for measuring indoor and outdoor (222)Rn concentrations in air. These are designed to respond only to (222)Rn and not to (220)Rn by restricting diffusional entry area. Such radon EIC (R EIC) monitors are modified by increasing the entry area to allow (220)Rn, in addition to (222)Rn. Such modified un...

متن کامل

MEASUREMENT OF ""Rn (THORON) USING ELECTRET ION CHAMBERS

Recently there has been an increased interest in the measurement of airborne ""Rn (thoron). Such measurements are particularly targeted in areas rich in thorium, and in facilities processing thorium compounds and associated radioactive wastes. Standard electret ion chambers @-PERMSR)* designed for making indoor and outdoor "^Rn (radon) measurement have very little response to "¡R (thoron). How...

متن کامل

Radon monitor calibration using NIST radon emanation standards: steady flow method.

The National Institute of Standards and Technology (NIST) polyethylene-encapsulated 226Ra/222Rn emanation (PERE) standards (old SRM 4968 and new SRMs 4971, 4972, and 4973) provide precise radon emanation rate, certified to a high degree of accuracy (approximately to 2%). Two new SRM 4973 standards containing totally 1036 Bq (0.028 microCi) of 226Ra, emanate 0.114 Bq (3.08 pCi) of 222Rn per min....

متن کامل

Nist Traceable Radon Calibration System for Calibrating

The NIST (National Institute of Standards and Technology) has recently made available 222Rn emanation standards for test and evaluation. The NIST certified parameters include the ^ ~ a strength and the emanation coefficient. When such a source is loaded into a radon leak tight enclosure of a known volume, 222~n accumulates over time and it is possible to calculate precisely the time integrated ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007