چکیده

Laser Doppler anemometer (LDA) experiments were performed to gain quantitative information on the differences between the large-scale flow phenomena in a non-stenosed and a stenosed model of the carotid artery bifurcation. The influence of the presence of the stenosis was compared to the effect of flow pulse variation to evaluate the feasibility of early detection of stenosis in clinical practice. Three-dimensional Plexiglass models of a non-stenosed and a 25% stenosed carotid artery bifurcation were perfused with a Newtonian fluid. The flow conditions approximated physiological flow. The results of the velocity measurements in the non-stenosed model agreed with the results from previous hydrogen-bubble visualization. A shear layer separated the low-velocity area near the non-divider wall from the high-velocity area near the divider wall. In this shear layer, vortex formation occurred during the deceleration phase of the flow pulse. The instability of this shear layer dictated the flow disturbances. The influences of the mild stenosis, located at the non-divider wall, was mainly limited to the stability of the shear layer. No disturbances were found downstream of the stenosis near the non-divider wall. Using a pulse wave with an increased systolic deceleration time, the velocity distribution showed an extended region with reversed flow, a more pronounced shear layer and increased vortex strength. From these measurements it is obvious that the influence of the presence of a mild stenosis, mainly limited to the stability of the shear layer, can hardly be distinguished from the effects of a variation of the flow pulse. From this it can be concluded that methods for detection of mild stenosis, using solely the large-scale flow phenomena, as can be measured by ultrasound or MRI techniques, will hardly have any clinical relevance.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mathematical modeling of blood flow in a stenosed artery under MHD effect through porous medium

In this investigation, a mathematical model for studying oscillatory flow of blood in a stenosed artery under the influence of transverse magnetic field through porous medium has been developed. The equations of motion of blood flow are solved analytically. The analytical expressions for axial velocity, volumetric flow rate, pressure gradient, resistance to blood flow and shear stress have been...

متن کامل

Vibration Analysis of Carotid Arteries Conveying Non-Newtonian Blood Flow Surrounding by Tissues

The high blood rate that often occurs in arteries may play a role in artery failure and tortuosity which leads to blackouts, transitory ischemic attacks and other diseases. However, vibration and instability analysis of carotid arteries are lacking. The objective of this study is to investigate the vibration and instability of the carotid arteries conveying blood under axial tension with surrou...

متن کامل

Evaluation of the Effect of Simplified and Patient-specific Arterial Geometry on Hemodynamic Flow in Stenosed Carotid Bifurcation Arteries

Numerous CFD studies have been performed on the motivation to elucidate the role of hemodynamic forces in the development of atherosclerosis in the coronary arteries and the carotid bifurcation artery. In order to improve CFD predictions, and to consider CFD as a clinical diagnostic or treatment planning tool, there is a need to ensure its accuracy and reliability through a systematic approach ...

متن کامل

Hemodynamic conditions of patient-specific carotid bifurcation based on ultrasound imaging Corresponding author:

The purpose of this paper is to complement the characterization of patient-specific carotid artery bifurcation hemodynamics based on image data obtained by Doppler ultrasound imaging. A methodology for patient-specific 3D luminal surface reconstruction followed by structured hexahedral meshing of the volume and blood flow simulation is presented. Quantitative descriptors of the flow based on wa...

متن کامل

Mathematical Modeling of Micropolar Blood Flow in a Stenosed Artery Under the Body Acceleration and Magnetic Field

Blood flow is modeled as non-Newtonian micropolar fluid. The non-linear governing equations of continuum and momentum in the cylindrical coordinate are being discretized using a finite difference approach and have been solved iteratively ,through Crank-Nicolson method. The blood velocity distribution, volumetric flow rate and Resistance to blood flow at the stenosis throat are computed for vari...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomechanics

دوره 29 11  شماره 

صفحات  -

تاریخ انتشار 1996