SWIFT detection of SPIO-labeled stem cells grafted in the myocardium.
نویسندگان
چکیده
We report initial results from studies using sweep imaging with Fourier transformation (SWIFT) to detect superparamagnetic iron oxide (SPIO) particle-labeled stem cells in the rat heart. In experiments performed on phantoms containing titanium balls or SPIO-labeled cells, frequency-shifted signals surrounding the paramagnetic objects produced a pileup artifact visualized by SWIFT. Total signal intensity was retained to a much greater extent by SWIFT as compared to gradient echo imaging. SWIFT imaging of excised and in vivo hearts showed (a) reduced blooming artifact as compared with gradient echo imaging, which helped reduce ambiguity in the detection of SPIO-labeled cells; (b) enhancement of off-resonance signals relative to the background in the imaginary component of images; and (c) detailed myocardial anatomy in magnitude images, which provided anatomic reference. These features suggest SWIFT can facilitate the detection of SPIO-laden cells in the cardiovascular system.
منابع مشابه
Embryonic stem cell grafting in normal and infarcted myocardium: serial assessment with MR imaging and PET dual detection.
PURPOSE To use magnetic resonance (MR) imaging and positron emission tomography (PET) dual detection of cardiac-grafted embryonic stem cells (ESCs) to examine (a) survival and proliferation of ESCs in normal and infarcted myocardium, (b) host macrophage versus grafted ESC contribution to serial MR imaging signal over time, and (c) cardiac function associated with the formation of grafts and whe...
متن کاملIterative reconstruction for off-resonance effects in SWIFT imaging
Introduction: Strong local field inhomogeneities are challenging for MRI. The challenges are 3 fold: excite the larger bandwidth, acquire the signal from regions with short T2*, and determine the correct and undistorted spatial frequency of the signal. The excitation and acquisition of fast relaxing signals are well captured by the SWIFT [2] sequence. Even with high bandwidth, as used for SWIFT...
متن کاملLetter by Sadek and Garry regarding article, "Iron-oxide labeling and outcome of transplanted mesenchymal stem cells in the infarcted myocardium".
BACKGROUND Cell labeling with superparamagnetic iron oxide (SPIO) nanoparticles enables noninvasive MRI and tracking of transplanted stem cells. We sought to determine whether mesenchymal stem cell (MSC) outcome is affected by SPIO labeling in a rat model of myocardial infarction. METHODS AND RESULTS Rat MSCs were labeled with SPIO (ferumoxides; Endorem; Guerbet, Villepinte, France). By trypa...
متن کاملEffects of iron oxide nanoparticles on cardiac differentiation of embryonic stem cells.
The therapeutic potential of transplantation of embryonic stem cells (ESCs) in animal model of myocardial infarction has been consistently demonstrated. The development of superparamagnetic iron oxide (SPIO) nanoparticles labeling and cardiac magnetic resonance imaging (MRI) have been increasingly used to track the migration of transplanted cells in vivo allowing cell fate determination. Howeve...
متن کاملIron-Oxide Labeling and Outcome of Transplanted Mesenchymal Stem Cells in the Infarcted Myocardium
Background—Cell labeling with superparamagnetic iron oxide (SPIO) nanoparticles enables noninvasive MRI and tracking of transplanted stem cells. We sought to determine whether mesenchymal stem cell (MSC) outcome is affected by SPIO labeling in a rat model of myocardial infarction. Methods and Results—Rat MSCs were labeled with SPIO (ferumoxides; Endorem; Guerbet, Villepinte, France). By trypan-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 63 5 شماره
صفحات -
تاریخ انتشار 2010