Intracoronary ultrasound in cardiac transplant recipients. In vivo evidence of "angiographically silent" intimal thickening.
نویسندگان
چکیده
BACKGROUND Accelerated coronary atherosclerosis is a major factor limiting allograft longevity in cardiac transplant recipients. Histopathology studies have demonstrated the insensitivity of coronary angiography for detecting early atheromatous disease in this patient population. Intracoronary ultrasound is a new imaging technique that provides characterization of vessel wall morphology. The purpose of this study was to compare in vivo intracoronary ultrasound with angiography in cardiac transplant recipients. METHODS AND RESULTS The left anterior descending coronary artery was studied with intracoronary ultrasound in 80 cardiac transplant recipients at the time of routine screening coronary angiography 2 weeks to 13 years after transplantation. A mean and index of intimal thickening were obtained at four coronary sites. Intimal proliferation was classified as minimal, mild, moderate, or severe according to thickness and degree of vessel circumference involved. Twenty patients were studied within 1 month of transplantation and had no angiographic evidence of coronary disease. An intimal layer was visualized by ultrasound in only 13 of these 20 presumably normal hearts. The 60 patients studied 1 year or more after transplantation all had at least minimal intimal thickening. Twenty-one patients (35%) showed minimal or mild, 17 (28%) moderate, and 21 (35%) severe thickening. Forty-two of these 60 patients had angiographically normal coronary arteries, 21 (50%) of whom had either moderate or severe thickening. All 18 patients with angiographic evidence of coronary disease had moderate or severe intimal thickening, but there was no statistically significant difference in intimal thickness or index when compared with the patients with moderate or severe proliferation and normal angiograms (thickness, 0.53 +/- 0.35 mm versus 0.64 +/- 0.30 mm, p = NS; index, 0.28 +/- 0.10 versus 0.34 +/- 0.10, p = NS). CONCLUSIONS The majority of patients 1 or more years after cardiac transplantation have ultrasound evidence of intimal thickening not apparent by angiography. Intracoronary ultrasound offers early detection and quantitation of transplant coronary disease and provides characterization of vessel wall morphology, which may prove to be a prognostic marker of disease.
منابع مشابه
Cardiac Transplant Recipients In Vivo Evidence of "Angiographically Silent" Intimal Thickening
Background. Accelerated coronary atherosclerosis is a major factor limiting allograft longevity in cardiac transplant recipients. Histopathology studies have demonstrated the insensitivity of coronary angiography for detecting early atheromatous disease in this patient population. Intracoronary ultrasound is a new imaging techniquSe that provides characterization of vessel wall morphology. The ...
متن کاملFeasibilit of Serial Intracoronary Ultrasound Imaging for Assessment of Progression of Intimal Proliferation in Cardiac Transplant Recipients
Background Serial quantitative coronary angiography is used to assess progression of coronary disease; however, pathology studies have demonstrated angiographic insensitivity for determining atheroma. Intracoronary ultrasound (ICUS) can define and measure the components of the arterial wall and offers the potential for precise quantitative assessment of disease progression on serial examination...
متن کاملFeasibility of serial intracoronary ultrasound imaging for assessment of progression of intimal proliferation in cardiac transplant recipients.
BACKGROUND Serial quantitative coronary angiography is used to assess progression of coronary disease; however, pathology studies have demonstrated angiographic insensitivity for determining atheroma. Intracoronary ultrasound (ICUS) can define and measure the components of the arterial wall and offers the potential for precise quantitative assessment of disease progression on serial examination...
متن کاملIntracoronary ultrasound assessment of morphological and functional abnormalities associated with cardiac allograft vasculopathy.
BACKGROUND The diffuse nature of cardiac allograft vasculopathy makes early detection of the disease by traditional noninvasive methods or coronary angiography difficult. The aim of this study was to determine if there is a relation between abnormalities in vessel wall morphology, as assessed by intracoronary ultrasound, and a decreased vasodilatory response to the endothelium-dependent vasodil...
متن کاملNitroglycerin-induced coronary vasodilation in cardiac transplant recipients. Evaluation with in vivo intracoronary ultrasound.
BACKGROUND Coronary artery vasomotion is altered after cardiac transplantation. The impact of accelerated transplant coronary atherosclerosis and myocardial rejection on vasomotion is not well understood. Intravascular ultrasound is a new imaging method with the ability to study real-time changes in coronary artery dimensions. METHODS AND RESULTS Epicardial coronary artery response to nitrogl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 85 3 شماره
صفحات -
تاریخ انتشار 1992