Blood pressure measurement: arm circumference and cuff size availability.
نویسندگان
چکیده
To avoid inaccurate blood pressure (BP) readings, the American Heart Association (AHA) recommends cuff width (CW) encircling 40% of the arm circumference (AC) and cuff length at least 80-100%. This study aimed to identify inpatients AC, the corresponding cuff size and the cuff size availability. In total, 81 AC were measured in the right arm. The cuff sizes to fit them were calculated according to AHA AC/CW width 0.40 ratio. The AC varied from 17.5 to 40.5 cm and the corresponding cuff width from 6 to 16 cm. The standard cuff 12 by 23 cm, the only size available in the clinics, was appropriate for only 17.3% of the subjects, whose AC varied between 32.5 and 34.3 cm. The lack of availability of different cuff sizes continues being a challenging problem to be faced. The standard cuff available, 12 cm large, did not fit 82.7% of the identified AC, resulting in over or underestimated BP registers.
منابع مشابه
Arm cuff in the measurement of blood pressure.
Selection of an arm cuff of the right size is necessary for accurate measurement of blood pressure (BP). Incorrect measurement can result either in unnecessary investigations, treatment, and follow-up for the mistaken diagnosis of hypertension, or no treatment for hypertension in individuals mistakenly thought to have normal BP. This is of particular importance in children, who have age-depende...
متن کاملBlood pressure measurement in adults: large cuffs for all?
STUDY OBJECTIVE The aim of the study was to determine whether a single size of cuff for adult blood pressure measurements is appropriate for general clinical practice. DESIGN The study was a prospective survey of a sample of adult blood pressure measurements using two cuffs with different bladder sizes (12 X 23 cm and 15 X 33 cm) in a randomised design using a random zero sphygmomanometer. ...
متن کاملMiscuffing: a problem with new guidelines.
Miscuffing: A Problem With New Guidelines To the Editor: Cuff dimensions have been a source of controversy for many years. Early guidelines of the American Heart Association recommended a cuff width 20% wider than the diameter of the arm or thigh and a cuff length “sufficient to half-encircle a limb . . . provided care is taken by the operator to place it on the side of the compressible artery....
متن کاملAn adjustable blood pressure cuff to correct errors due to variations in arm circumference.
A well-recognized source of error in the indirect measurement of blood pressure results from using the standard sphygmomanometer cuff for arms of widely different diameters (Pickering, 1955). When the arm is thicker than usual, blood pressure readings are higher than those obtained by direci intra-arterial measurement; when the arm is thinner; the readings are lower. Hence, for correct indirect...
متن کاملRecommendations for blood pressure measurement in human and experimental animals; part 1: blood pressure measurement in humans.
To the Editor: The members of the Atherosclerosis, Hypertension, and Obesity in the Young Committee of the American Heart Association Council on Cardiovascular Disease in the Young believe it is of clinical importance to point out a discrepancy in the cuff size section of the recent American Heart Association Scientific Statement “Recommendations for Blood Pressure Measurement in Humans.”1 On p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista latino-americana de enfermagem
دوره 17 4 شماره
صفحات -
تاریخ انتشار 2009