Experimental assessment of four ultrasound scattering models for characterizing concentrated tissue-mimicking phantoms.
نویسندگان
چکیده
Tissue-mimicking phantoms with high scatterer concentrations were examined using quantitative ultrasound techniques based on four scattering models: The Gaussian model (GM), the Faran model (FM), the structure factor model (SFM), and the particle model (PM). Experiments were conducted using 10- and 17.5-MHz focused transducers on tissue-mimicking phantoms with scatterer concentrations ranging from 1% to 25%. Theoretical backscatter coefficients (BSCs) were first compared with the experimentally measured BSCs in the forward problem framework. The measured BSC versus scatterer concentration relationship was predicted satisfactorily by the SFM and the PM. The FM and the PM overestimated the BSC magnitude at actual concentrations greater than 2.5% and 10%, respectively. The SFM was the model that better matched the BSC magnitude at all the scatterer concentrations tested. Second, the four scattering models were compared in the inverse problem framework to estimate the scatterer size and concentration from the experimentally measured BSCs. The FM did not predict the concentration accurately at actual concentrations greater than 12.5%. The SFM and PM need to be associated with another quantitative parameter to differentiate between low and high concentrations. In that case, the SFM predicted the concentration satisfactorily with relative errors below 38% at actual concentrations ranging from 10% to 25%.
منابع مشابه
Experimental Validation of the Spectral Fit Algorithm Using Tissue Mimicking Phantoms
Characterizing tissue by measuring its physical properties has potential for improving the diagnostic capabilities of medical ultrasound. One parameter that is estimated using the power spectrum of backscattered ultrasound echoes is the characteristic size or correlation length of the tissue microstructure responsible for the scattering. Unfortunately, the characteristic size measurement has tr...
متن کاملUltrasound-modulated optical microscopy.
We demonstrate that microscopic imaging is feasible in ultrasound-modulated optical tomography (UOT) of soft biological tissues, using a high-frequency focused ultrasound transducer with a 75-MHz central frequency. Our experiments in tissue mimicking phantoms show that at an imaging depth of about 2 mm, an axial resolution better than 30 microm can be achieved, whereas the lateral resolution is...
متن کاملA review of tissue substitutes for ultrasound imaging.
The characterization and calibration of ultrasound imaging systems requires tissue-mimicking phantoms with known acoustic properties, dimensions and internal features. Tissue phantoms are available commercially for a range of medical applications. However, commercial phantoms may not be suitable in ultrasound system design or for evaluation of novel imaging techniques. It is often desirable to ...
متن کاملComparison of ultrasound attenuation and backscatter estimates in layered tissue-mimicking phantoms among three clinical scanners.
Backscatter and attenuation coefficient estimates are needed in many quantitative ultrasound strategies. In clinical applications, these parameters may not be easily obtained because of variations in scattering by tissues overlying a region of interest (ROI). The goal of this study is to assess the accuracy of backscatter and attenuation estimates for regions distal to nonuniform layers of tiss...
متن کاملEx vivo blood vessel imaging using ultrasound-modulated optical microscopy.
Recently we developed ultrasound-modulated optical microscopy (UOM) based on a long-cavity confocal Fabry-Perot interferometer (CFPI). This interferometer is used for real-time detection of multiply scattered light modulated by high frequency (30 to 75 MHz) ultrasound pulses propagating in an optically, strongly scattering medium. In this work, we use this microscope to study the dependence of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of the Acoustical Society of America
دوره 132 6 شماره
صفحات -
تاریخ انتشار 2012