Prospective comparison of valve regurgitation quantitation by cardiac magnetic resonance imaging and transthoracic echocardiography.
نویسندگان
چکیده
BACKGROUND Both transthoracic echocardiography (TTE) and cardiac magnetic resonance (CMR) imaging allow quantification of chronic aortic regurgitation (AR) and mitral regurgitation (MR). We hypothesized that CMR measurement of regurgitant volume (RVol) is more reproducible than TTE. METHODS AND RESULTS TTE and CMR performed on the same day in 57 prospectively enrolled adults (31 with AR, 26 with MR) were measured by 2 independent physicians. TTE RVol(AR) was calculated as Doppler left ventricular outflow minus inflow stroke volume. RVol(MR) was calculated by both the proximal isovelocity surface area method and Doppler volume flow at 2 sites. CMR RVol(AR) was calculated by phase-contrast velocity mapping at the aortic sinuses and RVol(MR) as total left ventricular minus forward stroke volume. Intraobserver and interobserver variabilities were similar. For AR, the Bland-Altman mean interobserver difference in RVol was -0.7 mL (95% confidence interval [CI], -5 to 4) for CMR and -9 mL (95% CI, -53 to -36) for TTE. The Pearson correlation was higher (P=0.001) between CMR (0.99) than TTE readers (0.89). For MR, the Bland-Altman mean difference in RVol between observers was -4 mL (95% CI, -21 to 13) for CMR compared with 0.7 mL (95% CI, -30 to 32) for the proximal isovelocity surface area and -10 mL (95% CI, -76 to 56) for TTE volume flow at 2 sites. Correlation was similar for CMR (0.94) versus TTE readers (0.90 for the proximal isovelocity surface area). CONCLUSIONS Compared with TTE, CMR has lower intraobserver and interobserver variabilities for RVol(AR), suggesting CMR may be superior for serial measurements. Although RVol(MR) is similar by TTE and CMR, variability in measured RVol by both approaches suggests that caution is needed in clinical practice.
منابع مشابه
Multiparametric Assessment of Post-Transcatheter Aortic Valve Replacement Paravalvular Regurgitation Grading by Transthoracic Echocardiography and Cardiac Magnetic Resonance
Purpose: Paravalvular regurgitation post-transcatheter valve replacement is associated with poor outcomes. The Valve Academic Research Consortium has defined qualitative and quantitative criteria for assessing paravalvular leak severity by transthoracic echocardiography. Cardiac magnetic resonance imaging is highly accurate and reproducible in measuring aortic flow volumes, and has been used fo...
متن کاملRight ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease
Introduction: In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...
متن کاملQuantitation of mitral regurgitation after percutaneous MitraClip repair: comparison of Doppler echocardiography and cardiac magnetic resonance imaging.
OBJECTIVE Percutaneous valve intervention for severe mitral regurgitation (MR) using the MitraClip is a novel technology. Quantitative assessment of residual MR by transthoracic echocardiography (TTE) is challenging, with multiple eccentric jets and artifact from the clips. Cardiovascular magnetic resonance (CMR) is the reference standard for left and right ventricular volumetric assessment. CM...
متن کاملQuantification of chronic functional mitral regurgitation by automated 3-dimensional peak and integrated proximal isovelocity surface area and stroke volume techniques using real-time 3-dimensional volume color Doppler echocardiography: in vitro and clinical validation.
BACKGROUND The aim of this study was to test the accuracy of an automated 3-dimensional (3D) proximal isovelocity surface area (PISA) (in vitro and patients) and stroke volume technique (patients) to assess mitral regurgitation (MR) severity using real-time volume color flow Doppler transthoracic echocardiography. METHODS AND RESULTS Using an in vitro model of MR, the effective regurgitant or...
متن کاملMultimodality imaging in transcatheter aortic valve implantation: comparison between cardiovascular magnetic resonance, cardiac computed tomography, transesophageal and transthoracic echocardiography
Multimodality imaging in transcatheter aortic valve implantation: comparison between cardiovascular magnetic resonance, cardiac computed tomography, transesophageal and transthoracic echocardiography Andrew Jabbour, Tevfik F Ismail, Ali Vazir, Isabelle Roussin, Ankur Gulati, Francisco Alpendurada, Sameer Zaman, Oluwatosin Sotubo, Saman S Zaman, Ashwin Krishnamoorthy, Simon Davies, Sanjay K Pras...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Cardiovascular imaging
دوره 6 1 شماره
صفحات -
تاریخ انتشار 2013