A Java Program for LRE-Based Real-Time qPCR that Enables Large-Scale Absolute Quantification
نویسنده
چکیده
BACKGROUND Linear regression of efficiency (LRE) introduced a new paradigm for real-time qPCR that enables large-scale absolute quantification by eliminating the need for standard curves. Developed through the application of sigmoidal mathematics to SYBR Green I-based assays, target quantity is derived directly from fluorescence readings within the central region of an amplification profile. However, a major challenge of implementing LRE quantification is the labor intensive nature of the analysis. FINDINGS Utilizing the extensive resources that are available for developing Java-based software, the LRE Analyzer was written using the NetBeans IDE, and is built on top of the modular architecture and windowing system provided by the NetBeans Platform. This fully featured desktop application determines the number of target molecules within a sample with little or no intervention by the user, in addition to providing extensive database capabilities. MS Excel is used to import data, allowing LRE quantification to be conducted with any real-time PCR instrument that provides access to the raw fluorescence readings. An extensive help set also provides an in-depth introduction to LRE, in addition to guidelines on how to implement LRE quantification. CONCLUSIONS The LRE Analyzer provides the automated analysis and data storage capabilities required by large-scale qPCR projects wanting to exploit the many advantages of absolute quantification. Foremost is the universal perspective afforded by absolute quantification, which among other attributes, provides the ability to directly compare quantitative data produced by different assays and/or instruments. Furthermore, absolute quantification has important implications for gene expression profiling in that it provides the foundation for comparing transcript quantities produced by any gene with any other gene, within and between samples.
منابع مشابه
A kinetic-based sigmoidal model for the polymerase chain reaction and its application to high-capacity absolute quantitative real-time PCR
BACKGROUND Based upon defining a common reference point, current real-time quantitative PCR technologies compare relative differences in amplification profile position. As such, absolute quantification requires construction of target-specific standard curves that are highly resource intensive and prone to introducing quantitative errors. Sigmoidal modeling using nonlinear regression has previou...
متن کاملAbsolute quantification of murine interleukine-4, interleukine- 10 and interferon-γ gene transcripts using Real Time PCR
The study of cytokines gene expression is quite important in various conditions of health and disease for the evaluation of clinical responses to new vaccination approaches. An absolute quantification is based on a calibration curve and production of standard controls to achieve more reliable results than in relative system. In this study we attempted to construct standard controls to evaluate ...
متن کاملAssessing the Performance Capabilities of LRE-Based Assays for Absolute Quantitative Real-Time PCR
BACKGROUND Linear regression of efficiency or LRE introduced a new paradigm for conducting absolute quantification, which does not require standard curves, can generate absolute accuracies of +/-25% and has single molecule sensitivity. Derived from adapting the classic Boltzmann sigmoidal function to PCR, target quantity is calculated directly from the fluorescence readings within the central r...
متن کاملMeasuring E. coli and bacteriophage DNA in cell sonicates to evaluate the CAL1 reaction as a synthetic biology standard for qPCR
We measured the impact of the presence of total Escherichia coli (E. coli) cellular material on the performance of the Linear Regression of Efficiency (LRE) method of absolute quantitative PCR (LRE qPCR), which features the putatively universal CAL1 calibration reaction, which we propose as a synthetic biology standard. We firstly used a qPCR reaction in which a sequence present in the lone gen...
متن کاملComparison of Methods for Relative Quantification of Gene Expression Using Real-time Pcr
1 Univ. of Ljubljana, Biotechnical Fac., Dept. of Animal Science, Groblje 3, SI-1230 Domžale, Slovenia and rapid quantification results (Pfaffl, 2001; Yuan et al., 2006). Because of the lacking consensus on how to best perform qPCR, MIQE guidelines have been developed to uniform qPCR experiment setup, optimization and data analysis, making the protocols comparable between different research gro...
متن کامل