Analysis of trace metals (Cu, Cd, Pb, and Fe) in seawater using single batch nitrilotriacetate resin extraction and isotope dilution inductively coupled plasma mass spectrometry.

نویسندگان

  • Jong-Mi Lee
  • Edward A Boyle
  • Yolanda Echegoyen-Sanz
  • Jessica N Fitzsimmons
  • Ruifeng Zhang
  • Richard A Kayser
چکیده

A simple and accurate low-blank method has been developed for the analysis of total dissolved copper, cadmium, lead, and iron in a small volume (1.3-1.5 mL per element) of seawater. Pre-concentration and salt-separation of a stable isotope spiked sample are achieved by single batch extraction onto nitrilotriacetate (NTA)-type Superflow(®) chelating resin beads (100-2400 beads depending on the element). Metals are released into 0.1-0.5 M HNO(3), and trace metal isotope ratios are determined by ICPMS. The benefit of this method compared to our previous Mg(OH)(2) coprecipitation method is that the final matrix is very dilute so cone-clogging and matrix sensitivity suppression are minimal, while still retaining the high accuracy of the isotope dilution technique. Recovery efficiencies are sensitive to sample pH, number of resin beads added, and the length of time allowed for sample-resin binding and elution; these factors are optimized for each element to yield the highest recovery. The method has a low procedural blank and high sensitivity sufficient for the analysis of pM-nM open-ocean trace metal concentrations. Application of this method to samples from the Bermuda Atlantic Time-Series Study station provides oceanographically consistent Cu, Cd, Pb, and Fe profiles that are in good agreement with other reliable data for this site. In addition, the method can potentially be modified for the simultaneous analysis of multiple elements, which will be beneficial for the analysis of large number of samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low Blank Preconcentration Technique for the Determination of Lead, Copper, and Cadmium in Small-Volume Seawater Samples by Isotope Dilution ICPMS.

A simple low-blank method is described for the analysis of Pb, Cu, and Cd in seawater using Mg(OH)(2) coprecipitation and isotope dilution inductively coupled plasma mass spectrometry (ICPMS). Here, 20-40 μL of 9 M aqueous NH(3) is mixed into a 1.3 mL seawater sample spiked with enriched isotopes of Pb, Cu, and Cd. After centrifugation, the supernatant is discarded and the Mg(OH)(2) precipitate...

متن کامل

An off-line automated preconcentration system with ethylenediaminetriacetate chelating resin for the determination of trace metals in seawater by high-resolution inductively coupled plasma mass spectrometry.

A novel automated off-line preconcentration system for trace metals (Al, Mn, Fe, Co, Ni, Cu, Zn, Cd, and Pb) in seawater was developed by improving a commercially available solid-phase extraction system SPE-100 (Hiranuma Sangyo). The utilized chelating resin was NOBIAS Chelate-PA1 (Hitachi High-Technologies) with ethylenediaminetriacetic acid and iminodiacetic acid functional groups. Parts of t...

متن کامل

An improved method for rapid preconcentration and determination of bioactive trace metals in seawater using solid phase extraction and high resolution inductively coupled plasma mass spectrometry

Investigating how bioactive trace metals influence the cycling of macro-nutrients and carbon in oceanic and neritic environments is hindered by the labor-intensive and slow metal preconcentration methods currently available. We describe here a solid phase extraction method that rapidly preconcentrates a suite of bioactive trace metals from seawater. The ligand Ž . Ž . Ž bis 2-hydroxyethyl dithi...

متن کامل

Preconcentration and determination of trace metals in seawater using a thiol cotton fiber minicolumn coupled with inductively coupled plasma mass spectrometry.

A rapid separation and preconcentration method was developed for the determination of trace metals Cu, Zn, Cd, and Pb in seawater using a minicolumn packed with thiol cotton fiber (TCF) coupled with inductively coupled plasma mass spectrometry (ICP-MS). Preconcentration parameters, such as seawater sample volume and flow rate and eluent hydrochloric acid concentration, volume and flow rate, wer...

متن کامل

Trace Metals and Major Elements in Sediments of the Northern Persian Gulf

The concentrations of sixteen elements and organic carbon were determined in 78 marine sediment samples collected from the Iranian coastal waters of the Persian Gulf. Nine transects perpendicular to the coastline were sampled. Sixteen elements, including As, Ba, Cd, Co, Cu, Mn, Ni, Pb, Zn (trace metals) and Ca, Fe, Mg, Na, P, S, Si (major metals), were determined by Inductively Coupled Plasma M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytica chimica acta

دوره 686 1-2  شماره 

صفحات  -

تاریخ انتشار 2011