Single-photon emission computed tomography (SPECT) for assessment of hepatic lesions.
نویسندگان
چکیده
Single-photon emission computed tomography (SPECT) and conventional scintigraphy were compared in 130 patients examined to assess hepatic involvement in malignant disease. Transmission computed tomography (TCT) served as the reference method against which SPECT and conventional scintigraphy were compared. The sensitivity of SPECT was calculated for lesions grouped according to diameter as well as location. The Bayesian theorem was used to assess the reliability of both SPECT and conventional scintigraphy. SPECT identified only 52% of lesions with a diameter of 1.5-2.0 cm. It was also shown that the sensitivity of SPECT was lowest for small lesions in the middle third of the liver. A comparison of the final diagnosis demonstrated that SPECT had greater sensitivity, specificity, and accuracy than conventional scans, and is superior at low disease prevalence. At high disease prevalence, SPECT has a lower rate of false negatives. SPECT appears to be the superior imaging modality for evaluation of the liver in malignant disease.
منابع مشابه
Brain Single Photon Emission Computed Tomography Scan (SPECT) and Functional MRI in Systemic Lupus Erythematosus Patients with Cognitive Dysfunction: A Systematic Review
Objective(s): Systemic lupus erythematosus (SLE) is an autoimmune disease with a wide range of clinical manifestations. Cognitive dysfunction is one of the manifestations that could present prior to the emergence of any other neuropsychiatric involvements in SLE. Cognitive dysfunction is a subtle condition occurring with ahigh frequency. However, there is no data on the correlation of cognitive...
متن کاملUtilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures
Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...
متن کاملMonte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography
Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...
متن کاملImage Optimization in Single Photon Emission Computed Tomography by Hardware Modifications with Monte Carlo Simulation
Introduction: In Single Photon Emission Computed Tomography (SPECT), the projection data used for image reconstruction are distorted by several factors, including attenuation and scattering of gamma rays, collimator structure, data acquisition method, organ motion, and washout of radiopharmaceuticals. All these make reconstruction of a quantitative SPECT image very difficult. Simulation of a SP...
متن کامل18F-FDG PET/CT usefulness vs Tc99m-Tetrofosmin in the assessment of malignant brain gliomas: Report of two cases
Gliomas account for almost 80% of primary malignant brain tumors in adults. Magnetic Resonance imaging (MRI) is still the gold standard for diagnosis of brain tumors and brain 99mTc-tetrofosmin Single Photon Emission Computed Tomography (99mTc-tetrofosmin-SPECT) has been established as a useful tool for their evaluation. Fluorine-18–2-fluoro-2-deoxy-d-glucose positron emi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 23 12 شماره
صفحات -
تاریخ انتشار 1982