Magnetic resonance imaging-guided attenuation correction in whole-body PET/MRI using a sorted atlas approach
نویسندگان
چکیده
Quantitative whole-body PET/MR imaging is challenged by the lack of accurate and robust strategies for attenuation correction. In this work, a new pseudo-CT generation approach, referred to as sorted atlas pseudo-CT (SAP), is proposed for accurate extraction of bones and estimation of lung attenuation properties. This approach improves the Gaussian process regression (GPR) kernel proposed by Hofmann et al. which relies on the information provided by a co-registered atlas (CT and MRI) using a GPR kernel to predict the distribution of attenuation coefficients. Our approach uses two separate GPR kernels for lung and non-lung tissues. For non-lung tissues, the co-registered atlas dataset was sorted on the basis of local normalized cross-correlation similarity to the target MR image to select the most similar image in the atlas for each voxel. For lung tissue, the lung volume was incorporated in the GPR kernel taking advantage of the correlation between lung volume and corresponding attenuation properties to predict the attenuation coefficients of the lung. In the presence of pathological tissues in the lungs, the lesions are segmented on PET images corrected for attenuation using MRI-derived three-class attenuation map followed by assignment of soft-tissue attenuation coefficient. The proposed algorithm was compared to other techniques reported in the literature including Hofmann's approach and the three-class attenuation correction technique implemented on the Philips Ingenuity TF PET/MR where CT-based attenuation correction served as reference. Fourteen patients with head and neck cancer undergoing PET/CT and PET/MR examinations were used for quantitative analysis. SUV measurements were performed on 12 normal uptake regions as well as high uptake malignant regions. Moreover, a number of similarity measures were used to evaluate the accuracy of extracted bones. The Dice similarity metric revealed that the extracted bone improved from 0.58 ± 0.09 to 0.65 ± 0.07 when using the SAP technique compared to Hofmann's approach. This enabled to reduce the SUVmean bias in bony structures for the SAP approach to -1.7 ± 4.8% as compared to -7.3 ± 6.0% and -27.4 ± 10.1% when using Hofmann's approach and the three-class attenuation map, respectively. Likewise, the three-class attenuation map produces a relative absolute error of 21.7 ± 11.8% in the lungs. This was reduced on average to 15.8 ± 8.6% and 8.0 ± 3.8% when using Hofmann's and SAP techniques, respectively. The SAP technique resulted in better overall PET quantification accuracy than both Hofmann's and the three-class approaches owing to the more accurate extraction of bones and better prediction of lung attenuation coefficients. Further improvement of the technique and reduction of the computational time are still required.
منابع مشابه
Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction
Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...
متن کاملNew Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor
Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...
متن کاملVision 20/20: Magnetic resonance imaging-guided attenuation correction in PET/MRI: Challenges, solutions, and opportunities.
Attenuation correction is an essential component of the long chain of data correction techniques required to achieve the full potential of quantitative positron emission tomography (PET) imaging. The development of combined PET/magnetic resonance imaging (MRI) systems mandated the widespread interest in developing novel strategies for deriving accurate attenuation maps with the aim to improve t...
متن کاملPET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors
Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...
متن کاملAtlas-guided generation of pseudo-CT images for MRI-only and hybrid PET-MRI-guided radiotherapy treatment planning.
Magnetic resonance imaging (MRI)-guided attenuation correction (AC) of positron emission tomography (PET) data and/or radiation therapy (RT) treatment planning is challenged by the lack of a direct link between MRI voxel intensities and electron density. Therefore, even if this is not a trivial task, a pseudo-computed tomography (CT) image must be predicted from MRI alone. In this work, we prop...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical image analysis
دوره 31 شماره
صفحات -
تاریخ انتشار 2016