Preliminary Study in In Vivo CT Dosimetry Using Optically Stimulated Luminescence Detector (OSLD)
نویسندگان
چکیده
Optically stimulated luminescence nanoDot dosimeters (OSLD) have been used to measure single point dose distribution along the superior-inferior position at the surface (skin) and in depths, analogous to organ depths. A customized acrylic phantom of 46 cm length, 20 cm diameter was fabricated, and used for the experimental measurements using CT (Computed Tomography) beam. The CT dose profile along the surface and the centre of the phantom, as a function of scan field, were measured. The measured dose due to the primary radiation was quantified and compared with the theoretical dose profile using conventional 100 mm pencil CT ionization chamber. The OSLD responses at the center axial and the surface were found to be similar with the dose profile from CT ionization chamber. In this study, the dose at the center axial was found to be higher than the surface dose up to 28.13%. The dose at the diagonal center was found to be the highest compared to the surface dose up to 61.13%. The result of this work has revalidated the potential use of OSLD in CT dosimetry as an alternative to TL-dosimetry.
منابع مشابه
In vivo dosimetry and acute toxicity in breast cancer patients undergoing intraoperative radiotherapy as boost
PURPOSE To report the results of a correlation analysis of skin dose assessed by in vivo dosimetry and the incidence of acute toxicity. This is a phase 2 trial evaluating the feasibility of intraoperative radiotherapy (IORT) as a boost for breast cancer patients. MATERIALS AND METHODS Eligible patients were treated with IORT of 20 Gy followed by whole breast irradiation (WBI) of 46 Gy. A tota...
متن کاملOn the Use of Optically Stimulated Luminescent Dosimeter for Surface Dose Measurement during Radiotherapy
This study was carried out to investigate the suitability of using the optically stimulated luminescence dosimeter (OSLD) in measuring surface dose during radiotherapy. The water equivalent depth (WED) of the OSLD was first determined by comparing the surface dose measured using the OSLD with the percentage depth dose at the buildup region measured using a Markus ionization chamber. Surface dos...
متن کاملOptically stimulated luminescence in vivo dosimetry for radiotherapy: physical characterization and clinical measurements in (60)Co beams.
A commercial optically stimulated luminescence (OSL) dosimetry system was investigated for in vivo dosimetry in radiation therapy. Dosimetric characteristics of InLight dot dosimeters and a microStar reader (Landauer Inc.) were tested in (60)Co beams. The reading uncertainty of a single dosimeter was 0.6%. The reproducibility of a set of dosimeters after a single irradiation was 1.6%, while in ...
متن کاملCharacterization of optically stimulated luminescent dosimeters, OSLDs, for clinical dosimetric measurements.
Optically stimulated luminescent dosimeters, OSLDs, are plastic disks infused with aluminum oxide doped with carbon (Al2O3 : C). These disks are encased in a light-tight plastic holder. Crystals of Al2O3 : C when exposed to ionizing radiation store energy that is released as luminescence (420 nm) when the OSLD is illuminated with stimulation light (540 nm). The intensity of the luminescence dep...
متن کاملSU-E-T-509: Validation of the Use of OSLD for Carbon Beam Remote Dosimetry.
PURPOSE To describe the commissioning of Aluminum Oxide Optically Stimulated Luminescent Dosimeters (OSLD) for the use in Carbon beam remote dosimetry for centers participating in NCI-funded cooperative group clinical trials. METHODS As Carbon therapy centers express interest in participating in cooperative group clinical trials, the Imaging and Radiation Oncology Core Group (IROC) Houston QA...