Examination of the Refractive Index of Selected Samples of Glass for Forensic Purposes
نویسنده
چکیده
In the current work results of determinations of refractive index by the immersion method using a GRIM system were presented. 93 samples of glass collected in Poland from car windshields, window panes, car headlamps and glass containers were analysed. In this work an evaluation of the obtained results by chemometric methods was also presented. These chemometric methods are used to solve the problem of comparison of traces on the basis of values of refractive index determined for them.
منابع مشابه
Dispersion and Nonlinearity in Ultra-Optical Ga2O3 and TiO2-Bi2O3-PbO Glass Systems
Dispersion, as the characteristic variation of refractive index with wavelength, is more pronounced, where the wavelength is approaching to the absorption band. In ultra-optical glasses, the nonlinear refractive index, concerning to the light intensity dependent phenomenon, becomes considerable. Here, two ultra-optical property glass systems; TiO2-Bi2O3-PbO (TBP...
متن کامل“Study of stable gallium oxide heavey metal Ga2O3-Bi2O3-PbO system glasses proposed as a base for optically noble glazes and enamels”
Ultra optical glasses are proposed for attaining noble glazes of high reflection and shine. In addition, these glasses can be used as semi-mirrors and optical instruments. In this reseach attempts were devoted mainly to introduce a glass system with the highest possible refractive index in which the highest reflection is desirable. Thus different amounts of heavy metal oxides modifiers, such as...
متن کاملاثر شار اکسیژن بر روی ضریب شکست لایه اکسید آلومینیوم، لایهنشانی شده با روش تبخیر باریکه الکترونی
The effects of oxygen flow rate on refractive index of aluminum oxide film have been investigated. The Al2O3 films are deposited by electron beam on glass substrate at different oxygen flow rates. The substrate was heated to reach and the temperature was constant during the thin film growth. The transmittance spectrum of samples was recorded in the wavelength 400-800 nm. Then, using the maxim...
متن کاملForensic discrimination of sheet glass by a refractive-index measurement and elemental analysis with synchrotron radiation X-ray fluorescence spectrometry.
Measurements of the refractive index (RI) and elemental analysis using synchrotron radiation X-ray fluorescence spectrometry (SR-XRF) were applied to the forensic discrimination of sheet-glass samples from different origins. The refractive index was calculated from the matching temperature at which the glass fragments became invisible in silicone oil. Fragments smaller than 1 mm in maximum diam...
متن کاملEVALUATION OF PEG 4000 SOLUTION STABILITY IN DIFFERENT TEMPERATURES AND ENVIRONMENTAL CONDITIONS OVER THE TWELVE MONTHS
Background & Aims: Polyethylene glycol (PEG) solution is used as a laxative for the treatment of constipation in children. Due to the preparation of this solution as a compounding ingredient and solution instability as well as unavailability of the exact expiration date of compounding ingredients, it is necessary and important to investigate the stability of PEG solution. Materials & Methods: ...
متن کامل