Experimental procedure for the characterization of radiation damage in macromolecular crystals

نویسندگان

  • Ricardo M. F. Leal
  • Gleb P. Bourenkov
  • Olof Svensson
  • Darren Spruce
  • Matias Guijarro
  • Alexander N. Popov
چکیده

A reliable and reproducible method to automatically characterize the radiation sensitivity of macromolecular crystals at the ESRF beamlines has been developed. This new approach uses the slope of the linear dependence of the overall isotropic B-factor with absorbed dose as the damage metric. The method has been implemented through an automated procedure using the EDNA on-line data analysis framework and the MxCuBE data collection control interface. The outcome of the procedure can be directly used to design an optimal data collection strategy. The results of tests carried out on a number of model and real-life crystal systems are presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Towards an understanding of radiation damage in cryocooled macromolecular crystals.

Interest in radiation damage is growing rapidly owing to the surge in macromolecular crystallography experiments carried out at modern brilliant synchrotron macromolecular crystallography beamlines. Work on the characterization of radiation damage in cryocooled protein crystals is starting to have some impact on our understanding of the problem and of how damage might be affecting both the proc...

متن کامل

Experimental determination of the radiation dose limit for cryocooled protein crystals.

Radiation damage to cryocooled protein crystals during x-ray structure determination has become an inherent part of macromolecular diffraction data collection at third-generation synchrotrons. Generally, radiation damage is an undesirable component of the experiment and can result in erroneous structural detail in the final model. The characterization of radiation damage thus has become an impo...

متن کامل

Radiation damage in macromolecular crystallography: what is it and why should we care?

Radiation damage inflicted during diffraction data collection in macromolecular crystallography has re-emerged in the last decade as a major experimental and computational challenge, as even for crystals held at 100 K it can result in severe data-quality degradation and the appearance in solved structures of artefacts which affect biological interpretations. Here, the observable symptoms and ba...

متن کامل

Macromolecular Cryocrystallography

The current techniques for X-ray-diffraction data collection from macromolecular crystals at cryogenic temperatures are reviewed. The development of the experimental methods is outlined and the basic concepts pertaining to radiation damage and cryoprotection are summarized. Emphasis is placed on the practical aspects important to the success of the techniques, and a detailed account of these is...

متن کامل

Macromolecular cryocrystallography--methods for cooling and mounting protein crystals at cryogenic temperatures.

Cryocrystallography is routinely used in macromolecular crystallography laboratories. The main advantage of X-ray diffraction data collection near 100K is that crystals display much less radiation damage than seen at room temperature. Techniques and tools are described to facilitate cryoprotecting and flash-cooling crystals for data collection.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2011