Sonographic accuracy of estimated fetal weight in twins.

نویسندگان

  • Lorie M Harper
  • Kimberly A Roehl
  • Methodius G Tuuli
  • Anthony O Odibo
  • Alison G Cahill
چکیده

OBJECTIVES We aimed to determine the accuracy of sonographic formulas for estimating birth weight in twin pregnancies. METHODS We conducted a retrospective cohort study of consecutive twin pregnancies undergoing sonography at within 1 week of delivery. Pregnancies were included if biometric measurements and birth weight were available and excluded if anomalies were present. Estimated fetal weight was calculated using three sonographic formulas: two derived from singletons (Hadlock and Shepard) and one from twins (Ong). The correlation between estimated fetal weight and birth weight was determined using the Pearson correlation coefficient. The accuracy of each formula (bias) was assessed using the mean percentage error [(estimated fetal weight - birth weight)/birth weight × 100], and the precision (random error) was estimated from the standard deviation of the percentage error. The screening efficiency of each formula for intrauterine growth restriction, defined as below the 10th percentile on the Alexander growth standard, was assessed. The effect of twin presentation was determined using a paired analysis. RESULTS Of 1744 consecutive twin pregnancies, 270 (540 infants) met inclusion criteria. The estimated fetal weight of all 3 formulas strongly correlated with the birth weight (Pearson r = 0.90 for Hadlock, 0.87 for Shepard, and 0.92 for Ong). Each formula had similar sensitivity (65%-70%) and specificity (85%-90%) for intrauterine growth restriction. For each formula, the correlation coefficient was similar between twins A and B (Pearson r = 0.85-0.93); however, the estimated fetal weight for twin A tended to underestimate birth weight, whereas the estimated fetal weight for twin B tended to overestimate birth weight. CONCLUSIONS Three widely used estimated fetal weight formulas, two derived from singletons and one from twins, perform equally well in estimating birth weight in twin gestations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sonographic estimation of fetal weight in term pregnant women

Introduction: Deviation from normal fetal weight and growth contribute to morbidity and mortality in the perinatal period. Over 50 formulas for EFW (estimated fetal weight) have been published and yet the ideal formula has not been determined. The objective of this study was to evaluate the accuracy of sonographic estimation of fetal weight using Hadlock formula in comparison to birth weight....

متن کامل

Accuracy of sonographic fetal weight estimation within 14 days of delivery in a Jordanian population using Hadlock formula 1.

OBJECTIVES To assess the accuracy of sonographic fetal weight estimation within 14 days of delivery in a Jordanian population using Hadlock formula 1 in the third trimester. MATERIALS AND METHODS Estimated fetal weights and actual fetal weights data were collected from the medical records of pregnant women who had undergone sonographic fetal weight estimation within 14 days of delivery over t...

متن کامل

Sonographic fetal weight estimation prior to delivery: analysis of accuracy and interobserver variability between obstetrician and radiologist

The aim of this study was to evaluate the interobserver reliability of sonographic fetal weight estimation between experienced obstetrician and radiologist immadiately prior to delivery and to compare the sonographic accuracies of estimated fetal weights (EFW) between the sonographers. This was a prospective study of singleton pregnancies that underwent sonographic fetal weight estimation prior...

متن کامل

Sonographic prediction of fetal macrosomia: The relationship between estimated fetal weight and mode of delivery

Methods This is a retrospective cohort study carried out at the Orenburg Municipal Perinatal Center and Maternity Hospital No 2 from 2006 to 2012. In this study 3760 pregnancy outcomes were analyzed. The estimated fetal sonographic weight by Hadlock’s formula was obtained within the last week prior to delivery. The study population was divided into 4 groups (true positive, true negative, false ...

متن کامل

Estimation of fetal weight in fetuses with abdominal wall defects: comparison of 2 recent sonographic formulas to the Hadlock formula.

OBJECTIVE Estimation of fetal weight is particularly challenging in fetuses with abdominal wall defects (AWDs). We sought to compare the accuracy and screening efficiency for intrauterine growth restriction (IUGR) of 2 recent sonographic formulas to those of the Hadlock formula (Am J Obstet Gynecol 1985; 151:333-337) in fetuses with AWDs. METHODS This was a retrospective cohort study of fetus...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine

دوره 32 4  شماره 

صفحات  -

تاریخ انتشار 2013