Fluoroscopic views for safe insertion of lag screws into the posterior column of the acetabulum

نویسندگان

  • Wei Chen
  • Zekun Zhang
  • Yang Lu
  • Jia Li
  • Yingze Zhang
  • Yong Shen
چکیده

BACKGROUND Percutaneous lag screw fixation is an alternative treatment for non-displaced or minimally displaced posterior column fractures. This study aims to explore new fluoroscopic views of the acetabulum for safe percutaneous insertion of posterior column lag screws. METHODS Axial computed tomography (CT) scans were taken of sixteen embalmed adult cadavers. The axial CT images at the level of the middle height of the acetabulum were selected. The angle (angle α) between the posterior cortex of the posterior column (PCPC) and the line intersecting the axial plane and the coronal plane, and the angle (angle β) between the medial wall and the line intersecting the axial plane and the sagittal plane were identified and measured. Tangential views of the PCPC and medial wall were obtained by referencing the measured angles. A lag screw was inserted into the posterior columns of the sixteen pelvic specimens under fluoroscopic guidance using an iliac oblique view and the two tangential views. CT scans were performed to evaluate the lag screw position. Axial CT images of 52 volunteers were obtained and the angles α and β were measured following the same methods used for the cadaveric specimens. RESULTS The angles α and β for the specimens were 29.3 ± 2.8.1 and 8.1 ± 1.4 degrees, respectively. On the tangential view of the PCPC, the posterior cortex appears as a nearly straight line between the lesser and greater sciatic notches. On the tangential view of the medial wall, the medial wall appears as a distinct straight line. Using these radiographic images, the lag screws were inserted into the posterior columns of bony pelvic specimens. Screw placement was confirmed by CT, and found to be fully intraosseous in all cases without any cortical breaches. The angles α and β were 30.4 ± 4.1 and 9.2 ± 1.9 degrees for male volunteers and 28.5 ± 3.7 and 7.7 ± 1.8 degrees for female volunteers, significant difference in these angles between cadaveric specimens and human volunteers. CONCLUSION The tangential views of both the PCPC and medial wall can be obtained following the aforementioned methods The oblique iliac view and the two tangential views enable safe insertion of posterior column lag screws.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designation and Validation of a Posterior Anatomical Plate for the Anterior Column of the Acetabulum

BACKGROUND Surgical treatment of acetabular fractures is one of the greatest challenges for orthopedic surgeons. Fixation of most displaced fractures requires extensive exposure, which may lead to complications, including blood loss, neural or vascular injury, postoperative infection, wound healing problems, and heterotopic bone formation. MATERIAL AND METHODS This study was conducted to certif...

متن کامل

Comparison of Isocentric C-Arm 3-Dimensional Navigation and Conventional Fluoroscopy for Percutaneous Retrograde Screwing for Anterior Column Fracture of Acetabulum

Percutaneous screw insertion for minimally displaced or reducible acetabular fracture using x-ray fluoroscopy and computer-assisted navigation system has been advocated by some authors. The purpose of this study was to compare intraoperative conditions and clinical results between isocentric C-arm 3-dimensional (Iso-C 3D) fluoroscopy and conventional fluoroscopy for percutaneous retrograde scre...

متن کامل

Accuracy of Percutaneous Lumbosacral Pedicle Screw Placement Using the Oblique Fluoroscopic View Based on Computed Tomography Evaluations

STUDY DESIGN Retrospective. PURPOSE This study aims to investigate the accuracy of the oblique fluoroscopic view, based on preoperative computed tomography (CT) images for accurate placement of lumbosacral percutaneous pedicle screws (PPS). OVERVIEW OF LITERATURE Although PPS misplacement has been reported as one of the main complications in minimally invasive spine surgery, there is no com...

متن کامل

Single column locking plate fixation is inadequate in two column acetabular fractures. A biomechanical analysis

BACKGROUND The objective of this study was to determine whether one can achieve stable fixation of a two column (transverse) acetabular fracture by only fixing a single column with a locking plate and unicortical locking screws. We hypothesized that a locking plate applied to the anterior column of a transverse acetabular fracture would create a construct that is more rigid than a non-locking p...

متن کامل

Comparing the early function and complications between fluoroscopic guidance and blindly insertion of permanent hemodialysis catheter

Objective: Chronic kidney disease (CKD) is a complicated kidney defect causing permanent failure in renal function in progressive stages. Hemodialysis is the most accepted treatment to maintain body’s fluid/electrolyte homeostasis at the terminal stages of the disease. Permanent hemodialysis catheter (permicath) may be inserted blindly or by fluoroscopic guidance. This study aimed to compare th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014