Effect of propofol anaesthesia on the event-related potential mismatch negativity and the auditory-evoked potential N1.

نویسندگان

  • T P Simpson
  • A R Manara
  • N M Kane
  • R L Barton
  • C A Rowlands
  • S R Butler
چکیده

BACKGROUND Studies on the effects of anaesthesia on event-related potentials and long latency auditory-evoked potentials (AEP) are sparse. Both provide information on cortical processing and may have potential as monitors of awareness. We studied the effect of propofol on the event-related potential mismatch negativity (MMN) and the long-latency AEP NI. METHODS Twenty-one patients received 1 microgram ml-1 stepped increases in the target concentration of propofol using Diprifusor until a maximum of 6 micrograms ml-1 was achieved or the patient had lost consciousness. Neurophysiological responses (MMN and N1) and the patients' level of consciousness were recorded before the administration of propofol and at a target effector site concentration of propofol of 1, 2, 3, 4, and 6 micrograms ml-1. Grand average evoked potentials were computed at baseline, before the administration of propofol (A); at the highest propofol concentration at which each patient was responsive (B); and at the concentration of propofol at which the patient became unconscious (C). RESULTS Patients lost consciousness at different target concentrations of propofol, all being unresponsive by 4 micrograms ml-1. The response to the deviant stimuli used to elicit duration-shift MMN was significantly more negative than to the standard stimuli at A (mean difference 2.58 microV, P = 0.0011) but this difference was virtually abolished at point B, before the patients lost consciousness (mean difference 0.63 microV, P = ns). The amplitude of N1 evoked by standard stimuli was negative compared with electrical baseline at both point A (mean amplitude -3.81 microV, P < 0.001) and at point B (mean amplitude -2.2 microV, P = 0.002), but was no longer significantly different to baseline at point C (mean amplitude 0.51 microV, P = ns). The change in the mean amplitude of N1 from last awake (point B) to first unconscious (point C) was also significant (mean difference in amplitude 1.69 microV, P = 0.02). CONCLUSIONS MMN is unlikely to be a clinically useful tool to detect awareness in surgical patients. In contrast, the loss of N1 may identify the transition from consciousness to unconsciousness and deserves further study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Short- and long-term habituation of auditory event-related potentials in the rat

An auditory oddball paradigm in humans generates a long-duration cortical negative potential, often referred to as mismatch negativity. Similar negativity has been documented in monkeys and cats, but it is controversial whether mismatch negativity also exists in awake rodents. To this end, we recorded cortical and hippocampal evoked responses in rats during alert immobility under a typical pass...

متن کامل

Human electrophysiological examination of buildup of the precedence effect.

Event-related potential correlates of the buildup of precedence effect were examined. Buildup is a type of precedence effect illusion in which perception changes (from hearing two clicks to hearing one click) during a click train. Buildup occurs faster for right-leading than left-leading clicks. Continuous click trains that changed leading sides every 15 clicks were presented. Event-related pot...

متن کامل

Common N1 and mismatch negativity neural evoked components are revealed by independent component model-based clustering analysis.

Mismatch negativity (MMN) is an event-related brain potential that appears when an auditory regularity is violated. Two main hypotheses have been proposed to explain it: the adaptation hypothesis and the memory-based hypothesis. Critically, they differ in whether the MMN can be distinguished from the N1. In this study, we assessed the differential contribution of the N1 and the MMN using indepe...

متن کامل

The mismatch negativity cortical evoked potential elicited by speech in cochlear-implant users.

The mismatch negativity (MMN) event-related potential is a non-task related neurophysiologic index of auditory discrimination. The MMN was elicited in eight cochlear implant recipients by the synthesized speech stimulus pair /da/ and /ta/. The response was remarkably similar to the MMN measured in normal-hearing individuals to the same stimuli. The results suggest that the central auditory syst...

متن کامل

The mismatch negativity (MMN) and the McGurk effect

The McGurk illusory percept is obtained by dubbing an incongruent articulatory movement onto an auditory signal. The Mismatch Negativity (MMN) of the auditory Event-Related Potential (ERP) reflects the detection of a deviant stimulus within auditory short-term memory (STM) and besides an acoustic component, possesses, under certain conditions, a phonetic one. The present study assessed the exis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 89 3  شماره 

صفحات  -

تاریخ انتشار 2002