Comparison of three commercially available fit-test methods.

نویسندگان

  • Larry L Janssen
  • D Michael Luinenburg
  • Haskell E Mullins
  • Thomas J Nelson
چکیده

American National Standards Institute (ANSI) standard Z88.10, Respirator Fit Testing Methods, includes criteria to evaluate new fit-tests. The standard allows generated aerosol, particle counting, or controlled negative pressure quantitative fit-tests to be used as the reference method to determine acceptability of a new test. This study examined (1) comparability of three Occupational Safety and Health Administration-accepted fit-test methods, all of which were validated using generated aerosol as the reference method; and (2) the effect of the reference method on the apparent performance of a fit-test method under evaluation. Sequential fit-tests were performed using the controlled negative pressure and particle counting quantitative fit-tests and the bitter aerosol qualitative fit-test. Of 75 fit-tests conducted with each method, the controlled negative pressure method identified 24 failures; bitter aerosol identified 22 failures; and the particle counting method identified 15 failures. The sensitivity of each method, that is, agreement with the reference method in identifying unacceptable fits, was calculated using each of the other two methods as the reference. None of the test methods met the ANSI sensitivity criterion of 0.95 or greater when compared with either of the other two methods. These results demonstrate that (1) the apparent performance of any fit-test depends on the reference method used, and (2) the fit-tests evaluated use different criteria to identify inadequately fitting respirators. Although "acceptable fit" cannot be defined in absolute terms at this time, the ability of existing fit-test methods to reject poor fits can be inferred from workplace protection factor studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In Vitro Comparison of Soybean Lecithin Based-Extender with Commercially Available Extender for Ram Semen Cryopreservation

Background Egg yolk is the main cryoprotectant agent in semen freezing extenders which is used in order to protect spermatozoa against cold shock. However elimination of animal bioproducts from the cryopreservation protocol is becoming mandatory. Therefore the aim of this study is to compare a previously studied homemade soya bean lecithin based extender with a commercially available extender f...

متن کامل

The Comparison Between Goodness of Fit Tests for Copula

‎Copula functions as a model can show the relationship between variables‎. ‎Appropriate copula function for a specific application is a function that shows the dependency between data in a best way‎. ‎Goodness of fit tests theoretically are the best way in selection of copula function‎. ‎Different ways of goodness of fit for copula exist‎. ‎In this paper we will examine the goodness of fit test...

متن کامل

Fecal occult blood versus DNA testing: indirect comparison in a colorectal cancer screening population

BACKGROUND A multitarget stool DNA test (MSDT) that showed higher sensitivity but lower specificity than a fecal immunochemical test (FIT) for hemoglobin in one recent study from the US and Canada, is increasingly used for colorectal cancer (CRC) screening, despite its ~20-fold higher costs compared to FITs. We aimed to assess diagnostic performance of a quantitative FIT in an independent study...

متن کامل

Development of qRT-PCR Test for Quantification of Rubella Virus in Commercially Available Vaccines

vaccines is considered as a critical point and in-process of quality control (IPQC) test of vaccine production. Rapid tests, like real time PCR, are more appropriated when the production occurs at industrial scale because of the amounts of starting materials and the excess of consumed time required. In the current study, a real-time quantitative reverse transcription-polymerase chain reaction...

متن کامل

Comparison of dosimetry parameters of two commercially available Iodine brachytherapy seeds using Monte Carlo calculations

Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AIHA journal : a journal for the science of occupational and environmental health and safety

دوره 63 6  شماره 

صفحات  -

تاریخ انتشار 2002