Bone-implant interface around titanium implants under different loading conditions: a histomorphometrical analysis in the Macaca fascicularis monkey.
نویسندگان
چکیده
BACKGROUND Bone healing around endosseous dental implants is associated with peri-implant loading conditions. Therefore, the aim of this study was to evaluate histomorphometrically the bone response around unloaded, delayed, and immediately loaded implants with a progressive thread design that were placed in the posterior regions of the lower jaw in monkeys. METHODS Nine adult monkeys (Macaca fascicularis) were used in this study. After extraction of the second premolars and first and second molars in the mandible, the bone was allowed to heal for a period of 3 months. Forty-eight 8 mm long implants with a diameter of 3.5 mm were placed according to the following protocol. In two of the monkeys, six implants were placed and left to heal submerged for 3 months (group A). In seven monkeys, 21 implants were placed in one side of the mandible and loaded after 3 months of submerged healing (group B). The group B implants were loaded with temporary resin bridges at the same time as another 21 implants that were loaded immediately (group C) after placement in the contralateral side of the mandibles of the same monkeys. The occlusion of group B and C implants was checked for optimal relationship of the resin bridges that were replaced 1 month later with metal bridges and loaded for an additional 2 months. The group A animals were sacrificed after 3 months of submerged healing without loading; group B and C animals were sacrificed after 3 months of implant loading. Specimens were examined histologically and histomorphometrically. RESULTS All implants osseointegrated without presenting any gap in the metal-bone interface. Compact cortical bone was found in contact with the implant surfaces. Group A implants demonstrated in the interface cancellous bone with loose connective tissue. Group B and C implants showed a thick cortical plate with extensive bone trabeculae formation. There was a significant difference in bone-to-implant contact (BIC) between the various loading conditions. No significant difference (P < 0.05) was found between groups B and C. There was an increased area of bone (BA) within the threads as well as around the apices of group B and C implants. CONCLUSIONS Implant loading might have stimulated increased bone formation and thus may be a key factor in influencing positive osseointegration. In addition, immediately loaded implants may osseointegrate in a similar manner as delayed loaded implants.
منابع مشابه
Comparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study
Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...
متن کاملComparative Evaluation of Microgap at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study
Abstract Background and Aim : Microgap in the implant-abutment interface is one of the main challenges in the treatment of two-piece implants. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microgap at implant-abutment interface area under oblique cyclic loading in vitro. Methods and Materials In this in vitro study, 12 implant-abutment assemb...
متن کاملEvaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro
Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...
متن کاملتعیین توزیع تنش و کرنش استخوان اطراف ایمپلنت در طرح All-on-4 به روش آنالیز اجزای محدود
Background and Aims: The All-on-4 design with its significant advantages is an appropriate model in reconstruction of edentulous mandible. Evaluation of stress and strain distribution in this model is necessary for better judgment. The purpose of this FEA study was to measure stress and strain distribution on peri-implant bone in All-on-4 design in edentulous mandible. Materials and Methods: Th...
متن کاملHistologic and histomorphometric evaluation of peri-implant bone subjected to immediate loading: an experimental study with Macaca fascicularis.
PURPOSE Immediately loaded splinted implants can become osseointegrated when they are placed in the anterior part of the mandible. The concept of immediate loading has not been well examined in the posterior mandible. The aim of this study was to evaluate the hard tissue reactions around immediately loaded implants placed in the posterior mandible in the monkey model. MATERIALS AND METHODS Si...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of periodontology
دوره 74 10 شماره
صفحات -
تاریخ انتشار 2003