Percutaneous closure of paravalvular leak after transcatheter aortic valve replacement.

نویسندگان

  • Jane Luu
  • Omar Ali
  • Ted E Feldman
  • Matthew J Price
چکیده

An 86-year-old male underwent TAVR with a 26 mm Sapien valve, co valve, moderate-to-severe paravalvular AI persisted. The patient quick catheter was advanced across the tract over a stiff angled glidewire; a reduction of AI and rapid clinical recovery. (A) TEE long-axis and (B) shor confirms the 4-F MP catheter has been advanced outside the struts of th resulting in substantial reduction of AI by TEE in the (F) long-axis and (G multipurpose; RAO right anterior oblique; TAVR transcatheter aortic en Valve-invalve TAVR

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

Percutaneous Closure of an Aortic Prosthetic Paravalvular Leak with Device in a Patient Presenting with Heart Failure

Paravalvular leaks (PVLs) are a well-recognized complication of prosthetic valve replacement. Perivalvular prosthetic regurgitation causes significant morbidity and is associated with high perioperative mortality if open surgical repair is required. PVLs manifest with symptoms of congestive heart failure, hemolysis, or in most cases, the combination of both. In recent years, the development of ...

متن کامل

Transcatheter closure of paravalvular leaks: state of the art

Paravalvular leak (PVL) is a serious complication after surgical valve replacement or after transcatheter aortic valve replacement. Approximately 1-5% of PVLs can lead to serious clinical consequences, including congestive heart failure and/or haemolytic anaemia. For years, surgical re-intervention has been considered the treatment of choice for symptomatic patients with PVLs. However, surgical...

متن کامل

A Tricky Percutaneous Paravalvular Leak Closure Two Years After Implantation of 3f Enable Sutureless Bioprosthetic Aortic Valve.

Sutureless valves were designed in an attempt to simplify the aortic valve replacement procedure and reduce extracorporeal circuit time, whilst allowing complete excision of the calcified native valve using a minimally invasive approach. Elderly patients with significant comorbidities are considered to benefit the most, although randomized data are lacking. In registries of patients treated wit...

متن کامل

Rethinking percutaneous paravalvular leak closure: where do we go from here?

Paravalvular leak (PVL) is an uncommon yet serious complications associated with the implantation of surgical prosthetic valves and more recently recognized with transcatheter valves. Renewed interest has developed as relationships have emerged between the degree of paravalvular regurgitation and mortality. Percutaneous closure of PVLs has shown significant promise with contemporary success rat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular interventions

دوره 6 2  شماره 

صفحات  -

تاریخ انتشار 2013