Fluid responsiveness in acute circulatory failure.
نویسنده
چکیده
Although fluid resuscitation of patients having acute circulatory failure is essential, avoiding unnecessary administration of fluids in these patients is also important. Fluid responsiveness (FR) is defined as the ability of the left ventricle to increase its stroke volume (SV) in response to fluid administration. The objective of this review is to provide the recent advances in the detection of FR and simplify the physiological basis, advantages, disadvantages, and cut-off values for each method. This review also highlights the present gaps in literature and provides future thoughts in the field of FR. Static methods are generally not recommended for the assessment of FR. Dynamic methods for the assessment of FR depend on heart-lung interactions. Pulse pressure variation (PPV) and stroke volume variation (SVV) are the most famous dynamic measures. Less-invasive dynamic parameters include plethysmographic-derived parameters, variation in blood flow in large arteries, and variation in the diameters of central veins. Dynamic methods for the assessment of FR have many limitations; the most important limitation is spontaneous breathing activity. Fluid challenge techniques were able to overcome most of the limitations of the dynamic methods. Passive leg raising is the most popular fluid challenge method. More simple techniques have been recently introduced such as the mini-fluid challenge and 10-s fluid challenge. The main limitation of fluid challenge techniques is the need to trace the effect of the fluid challenges on SV (or any of its derivatives) using a real-time monitor. More research is needed in the field of FR taking into consideration not only the accuracy of the method but also the ease of implementation, the applicability on a wider range of patients, the time needed to apply each method, and the feasibility of its application by acute care physicians with moderate and low experience.
منابع مشابه
Is the pulse pressure variation a good predictor of fluid responsiveness in mechanically ventilated patients with low tidal volume?
A transversal and interventional study that included 30 critically ill patients with acute circulatory failure, sedated and mechanically ventilated with a tidal volume of 6 to 7 ml/kg. Mechanical ventilatory measurements including positive end-expiratory pressure plateau and peak pressures, static compliance and hemodynamic measurements including PPV, heart rate, mean systemic and pulmonary art...
متن کاملAn increase in aortic blood flow after an infusion of 100 ml colloid over 1 minute can predict fluid responsiveness: the mini-fluid challenge study.
BACKGROUND Predicting fluid responsiveness remains a difficult question in hemodynamically unstable patients. The author's objective was to test whether noninvasive assessment by transthoracic echocardiography of subaortic velocity time index (VTI) variation after a low volume of fluid infusion (100 ml hydroxyethyl starch) can predict fluid responsiveness. METHODS Thirty-nine critically ill v...
متن کاملNon-invasive assessment of fluid responsiveness by changes in partial end-tidal CO2 pressure during a passive leg-raising maneuver
BACKGROUND The passive leg-raising (PLR) maneuver provides a dynamic assessment of fluid responsiveness inducing a reversible increase in cardiac preload. Since its effects are sudden and transitory, a continuous cardiac output (CO) monitoring is required to appropriately assess the hemodynamic response of PLR. On the other hand, changes in partial end-tidal CO2 pressure (PETCO2) have been demo...
متن کاملRelation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure.
In mechanically ventilated patients with acute circulatory failure related to sepsis, we investigated whether the respiratory changes in arterial pressure could be related to the effects of volume expansion (VE) on cardiac index (CI). Forty patients instrumented with indwelling systemic and pulmonary artery catheters were studied before and after VE. Maximal and minimal values of pulse pressure...
متن کاملBrachial artery peak velocity variation to predict fluid responsiveness in mechanically ventilated patients
INTRODUCTION Although several parameters have been proposed to predict the hemodynamic response to fluid expansion in critically ill patients, most of them are invasive or require the use of special monitoring devices. The aim of this study is to determine whether noninvasive evaluation of respiratory variation of brachial artery peak velocity flow measured using Doppler ultrasound could predic...
متن کاملRespiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use
INTRODUCTION To investigate whether respiratory variation of inferior vena cava diameter (cIVC) predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure (ACF). METHODS Forty patients with ACF and spontaneous breathing were included. Response to fluid challenge was defined as a 15% increase of subaortic velocity time index (VTI) measured by transthoracic ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of intensive care
دوره 3 شماره
صفحات -
تاریخ انتشار 2015