Results of higher power toric intraocular lens implantation.

نویسندگان

  • Peter C Hoffmann
  • Sebastian Auel
  • Werner W Hütz
چکیده

PURPOSE To evaluate the efficacy, predictability, and safety of coaxial microincision phacoemulsification and toric intraocular lens (IOL) implantation in eyes with high corneal astigmatism. SETTING Two eye clinics in Germany. DESIGN Case series. METHODS Routine cataract extraction using 2.2 mm coaxial phaco equipment and Acrysof toric IOL (3.00 to 6.00 diopters [D] cylinder) implantation were performed. Examinations included optical biometry, Haigis IOL calculation, topography, and objective and subjective refractions. Retroillumination images were used to evaluate IOL alignment. Postoperative examinations were scheduled at 1 week and 3 months. RESULTS The study enrolled 40 eyes (30 patients). The mean preoperative keratometric cylinder was 3.55 ± 0.73 D (range 2.64 to 5.39 D) and the mean 3-month postoperative subjective cylinder, 0.67 ± 0.32 D. The mean logMAR uncorrected distance visual acuity improved from 0.93 to 0.20 and the mean logMAR CDVA, from 0.41 to 0.09. The mean prediction error (spherical equivalent) was +0.14 ± 0.44 D. The mean IOL rotation between 1 week and 3 months was 0.23 ± 1.9 degrees clockwise. The mean surgically induced astigmatism was 0.08 ± 0.41 D. The alignment error was below 10 degrees in 97.5% of cases. The mean vector change in refractive cylinder between 1 week and 3 months was 0.31 ± 0.19 D. The Alpins correction index was +1.01, indicating a slight tendency toward overcorrection. CONCLUSIONS Coaxial microincision phacoemulsification with toric IOL safely and predictably reduced high corneal astigmatism and improved surgical outcomes. Thorough planning and precise execution are necessary.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

IOLMaster keratometry for the calculation of toric intraocular lens power and orientation

In the implantation of intraocular lenses (IOL) stringent requirements are made on achieving the refractive target. This necessitates the exact determination of the basic data needed for IOL power calculation – both the axial length and, in particular, the corneal power – and additionally the cylinder power and its axis in the case of a toric lens. This gives rise to the question, especially fo...

متن کامل

Refractive surprise after toric intraocular lens implantation: graph analysis.

PURPOSE To determine the refractive cylinder effect of rotating a toric intraocular lens (IOL) and identify the sources of refractive astigmatic surprise after toric IOL implantation. SETTING Private practice, Melbourne, Australia. DESIGN Experimental study. METHODS Vergence formulas using a standard reduced eye model were used to bring all lens powers to the corneal plane. Double-angle v...

متن کامل

Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report

INTRODUCTION We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good visual outcomes in eyes with implantable collamer lens-induced cataract and astigmatism. CASE PRESENTATION A 53-year-old woman had undergone toric implan...

متن کامل

JOURNAL OF MEDICAL CASE REPORTS Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report

Introduction: We report the case of a patient in whom simultaneous toric phakic intraocular lens removal and phacoemulsification with toric intraocular lens implantation were beneficial for reducing pre-existing astigmatism and acquiring good visual outcomes in eyes with implantable collamer lens-induced cataract and astigmatism. Case presentation: A 53-year-old woman had undergone toric implan...

متن کامل

Comparison of the Astigmatic Power of Toric Intraocular Lenses Using Three Toric Calculators

PURPOSE To compare the astigmatic power of toric intraocular lenses (IOLs) obtained from the AcrySof, TECNIS, and iTrace toric calculator in patients with preoperative with-the-rule (WTR) or against-the-rule (ATR) corneal astigmatism. MATERIALS AND METHODS Fifty eyes with cataract and corneal astigmatism greater than 0.75 diopters were enrolled in each group (WTR and ATR). Keratometric values...

متن کامل

Treatment of Stable Keratoconus by Cataract Surgery with Toric IOL Implantation

We present the case of a 73-year-old patient who underwent successful phacoemulsification and toric intraocular lens (IOL) implantation to correct high stable astigmatism due to keratoconus and cataract. Preoperative refraction was –3.25 – 4.0 × 98°. A toric IOL (Acrysof SN60T6) with a spherical power of 16.5 D and a cylinder power of 3.75 D at the IOL plane and 2.57 D at the corneal plane was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 37 8  شماره 

صفحات  -

تاریخ انتشار 2011