Adiabatic inversion pulses for myocardial T1 mapping.
نویسندگان
چکیده
PURPOSE To evaluate the error in T1 estimates using inversion-recovery-based T1 mapping due to imperfect inversion and to perform a systematic study of adiabatic inversion pulse designs in order to maximize inversion efficiency for values of transverse relaxation (T2) in the myocardium subject to a peak power constraint. METHODS The inversion factor for hyperbolic secant and tangent/hyperbolic tangent adiabatic full passage waveforms was calculated using Bloch equations. A brute-force search was conducted for design parameters: pulse duration, frequency range, shape parameters, and peak amplitude. A design was selected that maximized the inversion factor over a specified range of amplitude and off-resonance and validated using phantom measurements. Empirical correction for imperfect inversion was performed. RESULTS The tangent/hyperbolic tangent adiabatic pulse was found to outperform hyperbolic secant designs and achieve an inversion factor of 0.96 within ±150 Hz over 25% amplitude range with 14.7 µT peak amplitude. T1 mapping errors of the selected design due to imperfect inversion was ∼4% and could be corrected to <1%. CONCLUSIONS Nonideal inversion leads to significant errors in inversion-recovery-based T1 mapping. The inversion efficiency of adiabatic pulses is sensitive to transverse relaxation. The tangent/hyperbolic tangent design achieved the best performance subject to the peak amplitude constraint.
منابع مشابه
Saturation pulse design for quantitative myocardial T1 mapping
BACKGROUND Quantitative saturation-recovery based T1 mapping sequences are less sensitive to systematic errors than the Modified Look-Locker Inversion recovery (MOLLI) technique but require high performance saturation pulses. We propose to optimize adiabatic and pulse train saturation pulses for quantitative T1 mapping to have <1 % absolute residual longitudinal magnetization (|MZ/M0|) over ran...
متن کاملHeart-rate independent myocardial T1-mapping using combined saturation and inversion preparation pulses
Background Myocardial T1 mapping remains a challenging task due to restrictions imposed by cardiac and respiratory motion. Modified Look-Locker Inversion Recovery (MOLLI) [1] is widely used for 2D cardiac T1-mapping. In MOLLI, the spin-lattice relaxation curve is sampled several times after a single magnetization preparation. The ECG triggered imaging induces a disturbance in the relaxation cur...
متن کاملHigh-resolution myocardial T1 mapping using single-shot inversion recovery fast low-angle shot MRI with radial undersampling and iterative reconstruction
OBJECTIVE To develop a novel method for rapid myocardial T1 mapping at high spatial resolution. METHODS The proposed strategy represents a single-shot inversion recovery experiment triggered to early diastole during a brief breath-hold. The measurement combines an adiabatic inversion pulse with a real-time readout by highly undersampled radial FLASH, iterative image reconstruction and T1 fitt...
متن کاملImproved segmented modified Look-Locker inversion recovery T1 mapping sequence in mice
OBJECT To develop and evaluate a 2D modified Look-Locker (MOLLI) for high-resolution T1 mapping in mice using a 3T MRI scanner. MATERIALS AND METHODS To allow high-resolution T1 mapping in mice at high heart rates a multi-shot ECG-triggered 2D MOLLI sequence was developed. In the proposed T1 mapping sequence the optimal number of sampling points and pause cardiac cycles following an initial a...
متن کاملCombined saturation/inversion recovery sequences for improved evaluation of scar and diffuse fibrosis in patients with arrhythmia or heart rate variability.
PURPOSE To develop arrhythmia-insensitive inversion recovery sequences for improved visualization of myocardial scar and quantification of diffuse fibrosis. METHODS A novel preparation pre-pulse, called saturation pulse prepared heart-rate-independent inversion recovery, is introduced, which consists of a combination of saturation and inversion pulses to remove the magnetization history in ea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 71 4 شماره
صفحات -
تاریخ انتشار 2014