3D cerebral angiography: radiation dose comparison with digital subtraction angiography.
نویسندگان
چکیده
BACKGROUND AND PURPOSE As the use of 3D rotational angiography (3D RA) for the evaluation of cerebral vasculature becomes more widespread, it is important to evaluate this imaging method's effect on patient radiation dose. The purpose of the study is to measure 3D RA radiation dose as compared with biplanar digital subtraction angiography (DSA). METHODS The distribution and peak skin dose were measured for 3D RA and biplanar DSA by using an anthropomorphic skull phantom. In addition, the cumulative incident dose, summed over all images in each acquisition, was determined. Measurements were acquired for our facility's standard 3D RA acquisition mode (25 degrees /s rotational speed; 162 total frames) and other available acquisition mode selections. RESULTS For 3D RA, the skin dose was found to be distributed across the back and sides of the skull with the peak skin dose located at the center of the back of the skull. The peak skin dose for the standard 3D RA acquisition mode was 15 mGy. For a biplanar DSA run, the peak skin dose was 58 mGy, also located at the back of the skull. The cumulative incident dose for the standard 3D RA acquisition mode was 33 mGy, compared with 53 mGy for biplanar DSA. CONCLUSION The patient radiation dose for 3D RA is significantly lower than for biplanar DSA, by nearly a factor of 4 in peak skin dose and 40% lower in cumulative incident dose.
منابع مشابه
Radiation Dose Reduction without Compromise to Image Quality by Alterations of Filtration and Focal Spot Size in Cerebral Angiography
OBJECTIVE Different angiographic protocols may influence the radiation dose and image quality. In this study, we aimed to investigate the effects of filtration and focal spot size on radiation dose and image quality for diagnostic cerebral angiography using an in-vitro model and in-vivo patient groups. MATERIALS AND METHODS Radiation dose and image quality were analyzed by varying the filtrat...
متن کاملEffective dose equivalents to patients undergoing cerebral angiography.
PURPOSE To determine values of the effective dose equivalent, HE, for patients undergoing diagnostic cerebral angiography and compare these values with radiation doses received by patients undergoing other diagnostic examinations of the head. METHODS The radiographic techniques for ten patients undergoing cerebral angiography were recorded and used to obtain the product of the entrance skin d...
متن کاملAnalysis of radiation doses incurred during diagnostic cerebral angiography after the implementation of dose reduction strategies.
BACKGROUND One goal of increasing awareness of radiation dose is to encourage personal and technical modifications in order to reduce the radiation exposure of patients and staff. OBJECTIVE To analyze the radiation doses incurred during diagnostic cerebral angiography and the angiographic techniques practiced over a 4-year period, in order to demonstrate the effectiveness of implementing radi...
متن کاملImproved Visualization of Intracranial Vessels with Intraoperative Coregistration of Rotational Digital Subtraction Angiography and Intraoperative 3D Ultrasound
INTRODUCTION Ultrasound can visualize and update the vessel status in real time during cerebral vascular surgery. We studied the depiction of parent vessels and aneurysms with a high-resolution 3D intraoperative ultrasound imaging system during aneurysm clipping using rotational digital subtraction angiography as a reference. METHODS We analyzed 3D intraoperative ultrasound in 39 patients wit...
متن کاملRadiation exposure from conventional and digital subtraction angiography of cerebral vessels.
Patients with atherosclerotic cerebrovascular disease were studied to determine the radiation exposure associated with conventional and digital subtraction angiography of the cerebral vessels. The median exposure-area product was 3198 R cm2 (range, 616-5665 R cm2) in the conventional angiography group and 1831 R cm2 (range, 366-4198 R cm2) in the IV digital subtraction angiography (DSA) group. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 26 8 شماره
صفحات -
تاریخ انتشار 2005