ECG and power line noise removal from respiratory EMG signal using adaptive filters
نویسندگان
چکیده
Marzieh Golabbakhsh, Monire Masoumzadeh, Mohammad Farzan Sabahi 1Medical Image and Signal Processing Research Center, Isfahan University of Medical Sciences, Iran. Email: [email protected] 2Electrical and Computer Engineering Department of University of Isfahan, Isfahan, Iran. Email: [email protected] Received: July 2011 Revised: October 2011 Accepted: November 2011 ABSTRACT: Surface electromyography (SEMG) from respiratory muscles is a non-invasive and effective method of studying neuromuscular diseases, muscle fatigue, enhancement of muscular function and also human-computer interface. This signal is contaminated by different noises. These include environmental noises like power line noise and also internal noises such as electrocardiographic noise. The clean EMG signal can be extremely useful for pathological purposes. In this study, diaphragmatic EMG signals were recorded with Power Lab system from seven subjects. The signals showed contamination due to power line interference (PLI) and also cardiac activity. Adaptive filters were used to reduce cardiac noise as well as 50 Hz (the fundamental) power line noise and its harmonics. Recursive least squares algorithm was used for the structure of the adaptive filter. Different values of the filter parameters; filter order and forgetting factor were examined for the noise removal purpose. Performance of the adaptive filter was quantified by signal-to-noise ratio and coherence measures for simulated data. The results show that we can successfully eliminate PLI and ECG noise from SEMG signals with adaptive filters. The figures and tables obtained help to decide which parameters of the filter are the best for our study.
منابع مشابه
Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique
Background: The electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful.Objective: Removing electrocardiogram contamination from electromyogram signals.Methods: In this paper, the clean electromyogram signal, electrocardiogram artifact and e...
متن کاملCorrigendum to: “Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique†published in J Biomed Phys Eng 2014; 4(1):31-38
متن کامل
Removal of Artifacts from ECG Signal Using RLS Based Adaptive Filter: A Review
The electrocardiogram (ECG) is used for diagnosis of heart diseases. In a few circumstances the recorded ECG signals are corrupted by various noise signals caused by power line interference, base line wander, electrode movement, muscular movement (EMG) etc. These noise signals are known as artifacts. These artifacts mislead the diagnosis of heart which is not desired. To avoid this problem caus...
متن کاملDenoising of ECG Signals with Adaptive Filtering Algorithms & Patch Based Method
ECG signals have been proven a very versatile tool for detection of cardiovascular diseases. But during recording of these signals, the ECG data gets contaminated by various noise signals caused by power line interference, base line wander, electrode movement, muscle movement (EMG) etc. These noise signals are known as artifacts. These artifacts mislead the diagnosis of heart which is not desir...
متن کاملNoise Removal from Surface Respiratory EMG Signal
The aim of this study was to remove the two principal noises which disturb the surface electromyography signal (Diaphragm). These signals are the electrocardiogram ECG artefact and the power line interference artefact. The algorithm proposed focuses on a new Lean Mean Square (LMS) Widrow adaptive structure. These structures require a reference signal that is correlated with the noise contaminat...