Why a Catheter Can Be Correctly Placed in the Anterior Horn of Lateral Ventricle by Inserting Perpendicular to the Frontal Bone on the Ventricular Drainage? Demonstration of the Accuracy of an Inserting Path by Computed Tomographic Image Study and Clinical Practices

نویسندگان

  • Kiyonobu IKEDA
  • Takashi ASAHI
  • Takaaki IIDA
  • Jiro YAMAMOTO
  • Tsuyoshi TSUKADA
  • Nobutaka YAMAMOTO
  • Fumihiko TAKEUCHI
  • Shigeru MUNEMOTO
  • Shu-ji SATO
  • Shuichi AKAIKE
  • Katsuo SHOIN
چکیده

Why a catheter can be correctly placed in the ventricle by inserting perpendicular to the frontal bone on the ventricular drainage? We performed a study on the accuracy of a path perpendicular to the skull surface into the anterior horn using computed tomography (CT), and a clinical study. Twenty patients were studied on CT images. Using the curved multi-planar reconstruction method, the curved frontal skull and brain were reconstructed to flat structures, and perpendicular lines were drawn from the flat surface to the foramen of Monro on the reconstructed images. In clinical practice, we made a device which guided a catheter inserting perpendicular to the frontal skull surface, and used it in the ventricular drainage surgery for 148 hydrocephalic patients (158 surgeries). We discovered that the curved surface of the frontal bone around Kocher's point represents the surface of a globe (mean radius, 75.9 ± 4.3 mm) centering on the foramen of Monro. The distribution of points ranged from 13.5-43.5 mm (mean, 43.5 ± 6.1 mm) to the midline, with points appearing more laterally as ventricular size increased. A catheter was placed in the ventricle in 148 surgeries (99.4%), and the catheter reached the ventricle with correct orientation toward the foramen of Monro in 128 (81.0%). The reason why the ventricular insertion perpendicular to the frontal bone surface can provide a consistent path toward the foramen of Monro is that the curved surface of the frontal bone around Kocher's point represents the surface of a globe centered on the foramen of Monro.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anatomic Reference for Computed Tomography of the Paranasal Sinuses and Their Openings in the Rayini Goat

Objective-  to provide a reference anatomy of the paranasal sinuses of the goat by using computed tomographic modality. Design- Experimented study.   Animals- Five male Rayini goats.   Procedures- CT images were acquired from the head region perpendicular to the hard palate. CT windows were adjusted as necessary to  obtain the optimal image for the paranasal sinuses. The images were studie...

متن کامل

Clinical significance of additional lateral imaging in diagnosis of prosthesis infection by combined Tc-99m labeled leukocyte/bone marrow scintigraphy

Introduction: Recently the most accurate diagnostic method in the diagnosis of prosthesis infection is the combination of Tc-99m labeled leukocyte/bone marrow imaging. However the diagnostic efficiency of the test is influenced because of its low spatial resolution. Recently SPECT/CT imaging is implicated in this test with efficient additional diagnostic improvement. In the dep...

متن کامل

Computed Tomographic Anatomy of the Bronchial Tree of the Jebeer Gazelle

Objectives- to provide a reference anatomy of the bronchial tree of the Jebeer Gazelle by using computed tomographic modality. Design- Experimental study. Animals- Three female Jebeer Gazelle Procedures- Spiral CT images were taken from the thoracic region perpendicular to long axis of the body. CT windows were adjusted as necessary to have optimized images of pulmonary organ. The images ...

متن کامل

بررسی قطر عرضی بطن سوم مغز در تصویرهای توموگرافی کامپیوتری بیماران مبتلا به اختلال افسردگی عمده

The objective of the present study was to compare the maximum width of the third ventricle(V3) in brain computed tomographic (CT) scans of patients with Major Depressive Disorder (MDD) and normal healthy controls in psychiatry clinics and wards of Iran University of Medical Sciences and radiology Department of Hazrat Rasoul Hospital. First, during a pilot study, interrater and intrara...

متن کامل

A Study on Robustness of Various Deformable Image Registration Algorithms on Image Reconstruction Using 4DCT Thoracic Images

Background: Medical image interpolation is recently introduced as a helpful tool to obtain further information via initial available images taken by tomography systems. To do this, deformable image registration algorithms are mainly utilized to perform image interpolation using tomography images.Materials and Methods: In this work, 4DCT thoracic images of five real patients provided by DI...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 57  شماره 

صفحات  -

تاریخ انتشار 2017