Comparison of indirect hemagglutination and indirect immunofluorescence tests with microneutralization tests for detection of type-specific Herpesvirus hominis antibody.
نویسندگان
چکیده
Indirect hemagglutinating and immunofluorescent antibody responses to Herpesvirus hominis types 1 and 2 were compared to neutralizing antibody responses in infected humans from whom H. hominis type 1 or 2 was isolated. The indirect immunofluorescent antibody test was shown to be the most sensitive and specific for primary human infections. The sensitivity and specificity of the indirect hemagglutination and the immunofluorescent antibody tests were shown to be equal to that of the microneutralization test among patients who had primary or recurrent H. hominis type 2 infections. It is suggested that the indirect hemagglutination test is preferable for assaying large populations for previous infection with H. hominis type 2 because it is rapid, easier to perform, and more economical. The intermediate range of titer differences (deltat) between H. hominis types 1 and 2 previously reported to be due to infections with both viruses was shown to occur in all three tests among patients with primary infections with either virus.
منابع مشابه
Micro indirect hemagglutination test for Cytomegalovirus.
In an effort to obtain the flexibility and ease of performance of a rapid, serological test for detection of cytomegalovirus antibody, the indirect hemagglutination (IHA) technique was investigated by using a microserological system. Antigens were prepared from tissue cultures of infected human fibroblasts. The specificity of the cytomegalovirus antibody response detected by the IHA test correl...
متن کاملReactivity of envelope, capsid, and soluble antigens of Herpesvirus hominis types 1 and 2 in the indirect hemagglutination test.
Envelope, capsid, and soluble antigens of Herpesvirus hominis (HVH) types 1 and 2 were compared to crude antigens (disrupted HVH-infected cells) for potency, type-specificity, and diagnostic value in the indirect hemagglutination (IHA) test. The envelope appeared to be the predominant component reacting in the IHA test, but recurrent HVH infections increased the reactivity of human sera with ca...
متن کاملDiagnosis of Herpesvirus hominis infections in a general hospital laboratory.
There is a greatly increased interest in Herpesvirus hominis infections especially those of type 2 associated with genital lesions or neonatal disease. Physicians are eager to confirm the clinical impression with a specific virologic diagnosis such as isolation of the agent and its typing, and type-specific antibody responses. Procedures are reviewed here which permit such studies in general mi...
متن کاملComparison between indirect immunofluorescence and microneutralization for detection of antibodies to polioviruses.
Indirect immunofluorescence and microneutralization methods for the detection of antibodies to poliovirus serotypes 1, 2, and 3 were compared. Of the 41 sera tested for poliovirus type 1 antibody, 40% were in complete agreement, 55% differed by one dilution, and 5% differed by two dilutions. For poliovirus type 2, 37 sera were tested; 56% completely agreed, and 44% differed by only one dilution...
متن کاملComparison of five methods of cytomegalovirus antibody screening of blood donors.
A group of 120 sera from blood donors was screened by complement fixation and commercially available immunofluorescence, solid-phase fluorescence immunoassay, enzyme-linked immunosorbent assay, and indirect hemagglutination tests. Twenty-four of the sera were positive by three or more of the five tests and judged to be true positives; 89 were negative by three or more of the tests and considere...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 9 3 شماره
صفحات -
تاریخ انتشار 1979