Accuracy analysis of a respirometer for activated sludge dynamic modelling.
نویسندگان
چکیده
The aim of the paper is to assess the experimental errors arising from the operation of a closed respirometer using autotrophic biomass. A closed, intermittent-flow device has been set-up for the measurement of oxygen uptake rate (OUR) and parameter calibration. After describing the device structure and operation, the factors affecting accuracy have been assessed. Inaccuracies may be caused by two groups of parameters: design parameters, including flow rate, volume, sampling time, numerical algorithm, sample injection and environmental parameters, concerning the physicochemical conditions of the experiment, such as unwanted oxygen transfer, pH, and the influence of sludge condition on "start-up" behaviour. It is shown to what extent each of them affects the final accuracy of the OUR measurement. In the second part of the paper, the respirometric data are used to calibrate a two-step nitrification model and their impact on the accuracy of the estimation of model parameters is assessed. Confidence limits are derived for the identifiable parameter combinations and the practical identifiability assessed with the aid of trajectory sensitivity analysis.
منابع مشابه
Application of Response Surface Methodology and Artificial Neural Network for Analysis of p-chlorophenol Biosorption by Dried Activated Sludge
Phenolic compounds are considered as priority pollutants because of their high toxicity at low concentration. In the present study, the sorption of p-chlorophenol (p-CP) by dried activated sludge was investigated. Activated sludge was collected as slurry from the sludge return line of a municipal wastewater treatment plant. Sorption experiments were carried out in batch mode. In order to invest...
متن کاملDynamic Performance Analysis and Simulation of a Full Scale Activated Sludge System Treating an Industrial Wastewater Using Artificial Neural Network
Due to changeable nature of the industrial wastewaters, proper operation of an industrial wastewater treatment plant is of prior importance in order to keep the process stability at the desired conditions. In this mean, simulation of the treatment system behavior using artificial neural network (ANN) can be an effective tool. This paper evaluates long term performance and process stability of ...
متن کاملPrevalence of antibiotic resistant genes in selected activated sludge processes in Isfahan Province, Iran
Wastewater treatment plants are one of the main sources of dissemination of antibiotic resistance genes (ARGs) into the environment. The present study was conducted to determine the prevalence and removal of ARGs in different wastewater treatment processes. A total of 36 samples from raw and final effluent of different activated sludge processes were collected and analyzed. Molecular analysis w...
متن کاملInhibition of activated sludge respiration by heavy metals
Inhibition of the respiration microbial activity in the activated sludge caused by heavy metal concentrations (Cr, Cd, Cu and Ni) was studied by means of respirometric method using Strathtox respirometer (Strathkelvin Glasgow).The studied sludge samples were obtained from the two waste water treatment plants with different types of pollution (municipal waste water and domestic waste water). Key...
متن کاملRespirometric analysis of activated sludge models from palm oil mill effluent.
Activated sludge models (ASMs) have been widely used as a basis for further model development in wastewater treatment processes. Values for parameters to be used are vital for the accuracy of the modeling approach. A continuous stirred tank reactor (CSTR), as open respirometer with continuous flow for 20 h is used in ASMs. The dissolved oxygen (DO) profile for 11 days was monitored. It was foun...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Water research
دوره 36 5 شماره
صفحات -
تاریخ انتشار 2002