Contact mechanics of the medial tibial plateau after implantation of a medial meniscal allograft. A human cadaveric study.

نویسندگان

  • M M Alhalki
  • M L Hull
  • S M Howell
چکیده

The goal of this study was to determine how well a medial meniscal allograft restores the normal contact mechanics of the medial tibial plateau at the time of implantation. We measured maximum pressure, mean pressure, and contact area of the intact human cadaveric knee, the knee after meniscectomy, the knee with the original meniscus removed and reimplanted as an autograft, and the knee with an allograft. Measurements were made using pressure-sensitive film in 10 specimens loaded in compression to 1000 N at 0 degrees, 15 degrees, 30 degrees, and 45 degrees of flexion. The autograft and the allograft were identically implanted by cementing bone plugs attached to the meniscal horns in anatomic transtibial tunnels and suturing the outer edge of the meniscus to the remnant of the original meniscus. A medial meniscal allograft did not consistently restore normal contact mechanics because the process of implantation and the degree of match between the original and allograft meniscus affected the immediate load-bearing performance of the transplant. However, the allograft did significantly reduce the contact pressure compared with the knee after meniscectomy. If the results from this study can be extrapolated to patients, then using an allograft to restore contact mechanics to normal may require improvements in surgical technique and graft selection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contact Mechanics of the Medial

The goal of this study was to determine how well a medial meniscal allograft restores the normal contact mechanics of the medial tibial plateau at the time of implantation. We measured maximum pressure, mean pressure, and contact area of the intact human cadaveric knee, the knee after meniscectomy, the knee with the original meniscus removed and reimplanted as an autograft, and the knee with an...

متن کامل

Nonanatomic location of the posterior horn of a medial meniscal autograft implanted in a cadaveric knee adversely affects the pressure distribution on the tibial plateau.

Nonanatomic placement of the posterior horn may occur during arthroscopic implantation of a meniscal transplant. The objective of this study was to determine whether nonantomic placement adversely affects the contact pressure distribution on the medial tibial plateau. Medial meniscal autografts were placed in eight cadaveric knees with the posterior horn tunnel in nonanatomic locations (5 mm me...

متن کامل

Effect of lateral meniscal allograft sizing on contact mechanics of the lateral tibial plateau: an experimental study in human cadaveric knee joints.

BACKGROUND A mismatch of the original lateral meniscus and a lateral meniscus allograft by inaccurate preoperative radiographic sizing can have significant consequences on ultimate function. HYPOTHESIS The size of a lateral meniscal allograft affects the contact mechanics of the femoral condyle on the tibial plateau. STUDY DESIGN Controlled laboratory study. METHODS Four right and 2 left ...

متن کامل

Time dependent properties of bovine meniscal attachments: stress relaxation and creep.

It has been suggested that the success of a meniscal replacement is dependent on several factors, one of which is the secure fixation and firm attachment of the replacement to the tibial plateau [Chen, M.I., Branch, T.P., et al., 1996. Is it important to secure the horns during lateral meniscal transplantation? A cadaveric study. Arthroscopy 12(2), 174-181; Alhalki, M.M., et al., 1999. How thre...

متن کامل

Identification of cross-sectional parameters of lateral meniscal allografts that predict tibial contact pressure in human cadaveric knees.

To guide the development of improved procedures for selecting meniscal allografts, the objective of this study was to identify which cross-sectional parameters of a lateral meniscal allograft predict the contact pressure of the articular surface of the tibia. To meet the objective, the contact pressure of the articular surface of the tibia was measured with a lateral meniscal autograft and a la...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of sports medicine

دوره 28 3  شماره 

صفحات  -

تاریخ انتشار 2000