Successive cases of an entrapped arterial catheter guidewire in separate patients on the same day.
نویسندگان
چکیده
To the Editor, We share our recent experiences with the Arrow International radial artery catheterization set (Ref RA04020, Reading, PA, USA). After general anesthesia was induced and our patient’s left radial artery was positioned and prepared, we introduced the Arrow catheter set into the site. Bright red blood was observed in the back flow tube that houses the guidewire. The guidewire was then advanced approximately 1 cm before gentle resistance was felt. Attempts at withdrawing the guidewire back into the catheter set were also met with resistance. Several additional attempts were made at withdrawal using slight traction and twisting on the guidewire, but without success. The Teflon outer catheter, guidewire, and introducer needle were then withdrawn together as a unit; however, the guidewire uncoiled, remained secure within the tissues, and could not be removed despite attempts to pull it out. An immediate intraoperative x-ray (Figure) was performed, which showed the intact uncoiled guidewire kinked within the tissues. A vascular surgical consult was requested, and after consultation, a surgical cut-down was performed to retrieve the guidewire that was imbedded 1 cm within the subcutaneous tissues, but not within the artery. The site was closed with two sutures and then the original surgical procedure was completed as planned without incident. Coincidently, another incident involving an entrapped guidewire occurred on this same day with another similar Arrow catheter kit. In this case, the introducer needle entered the patient’s radial artery, but partial advancement of the guidewire was met with resistance. When withdrawal of the guidewire was met with resistance, the entire apparatus was removed without further guidewire repositioning. This time the catheterization set was removed intact without difficulty. There have been many accounts describing the risk of guidewire entrapment, uncoiling, and fragmentation, and some clinicians have questioned guidewire design vs technique. With two consecutive incidences, we suspect a possible guidewire defect and not the technique employed, which was standard in both cases. In a previous report, a case similar to ours was described where the guidewire could not be retracted into the catheter and withdrawal of the whole unit was required. No uncoiling or guidewire complications occurred in this case. In our first described case, we attempted further withdrawal and used a twisting motion on the guidewire before attempting to remove the whole guidewire, introducer needle, and catheter apparatus simultaneously. Our experience re-emphasizes the risks associated with withdrawing any guidewire back through an introducer needle. While it is common practice to retract L. Garcia, MD (&) J. Davis, BSN T. Davis, AT N. Durrani, MD M. Welliver, DNP University of Florida at Shands, Jacksonville, FL, USA e-mail: [email protected]
منابع مشابه
Ultrasound detection of guidewire position during central venous catheterization.
INTRODUCTION Ultrasound guidance decreases complications of central venous catheter (CVC) placement, but risks of arterial puncture and inadvertent arterial catheter placement exist. Ultrasound-assisted detection of guidewire position in the internal jugular vein could predict correct catheter position before dilation and catheter placement. METHODS Ultrasound examinations were performed in a...
متن کاملThe entrapped central venous catheter.
The central venous catheter (CVC) is associated with numerous complications more so during the process of insertion. We report for the first time how an indwelling catheter was entrapped by a replacement catheter on the same side, after being speared by the introducer needle and guidewire. The diagnosis was made when there was difficulty in removing the old catheter. Subsequently, interventiona...
متن کاملComparing the Effect of Continuous and Intermittent Irrigation Techniques on Complications of Arterial Catheter and Partial Thromboplastin Time in Patients Following Coronary Artery Bypass Grafting Surgery
Background: Different approaches are available to irrigate the arterial catheter, such as continuous and intermittent techniques. However, there is a disagreement regarding the most appropriate method. Aim: this study aimed to compare the effect of two continuous and intermittent irrigation methods on complications of arterial catheter and partial thromboplastin time (PTT) in patients with coro...
متن کاملComparison of the Effects of Intralipid 10% and 20% on Peripheral Catheter Ablation in a Pediatric Intensive Care Unit
Background: Energy deficit is a common and serious problem in pediatric intensive care units. Parenteral nutrition, either alone or in combination with enteral nutrition, can improve nutrient delivery in critically ill patients by preventing or correcting the energy deficit and improving the outcomes. Intralipid 10% and 20% are lipid emulsions, widely used in parenteral nutrition. Despite sever...
متن کاملJ-tip spring guidewire entrapment by an inferior vena cava filter.
The number of complications between guidewires and inferior vena cava filters is unknown and most likely underreported. Since 1993, at least 17 cases of central venous catheter guidewires entangled in inferior vena cava filters have been reported. The placement of both devices in the intensive care setting has increased the number of incidents in which a guidewire from a central venous catheter...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Canadian journal of anaesthesia = Journal canadien d'anesthesie
دوره 57 12 شماره
صفحات -
تاریخ انتشار 2010