A Dissolved Oxygen Measurement Based on Fiber Optical Oxygen Sensor
نویسنده
چکیده
For the determination of dissolved oxygen, working principle of the fiber optic oxygen sensor is studied. The sensor system calibration method and temperature compensation measures and their maintenance methods are analyzed. The dissolved oxygen sensors current widely using oxygen electrode and optical fiber oxygen sensor are compared. Optical fiber probe sensor is used in the current system, the multiple points and multiple samples can achieve the simultaneous detection. Copyright © 2013 IFSA.
منابع مشابه
Optical Analyzer for Continuous Monitoring of Dissolved Oxygen in Aviation Fuel and Other Non-aqueous Media
A special sensitive element based on the novel composite material was created. The sensor has a linear calibration and is resistant to aliphatic hydrocarbons, in particular aviation fuel. A low cost and easy-to-implement method for calibrating the sensor was proposed. Temperature dependence of the oxygen mass transfer coefficient kL was measured for aviation fuel TS-1 (Russi...
متن کاملEmployment of Fluorescence Quenching for the Determination of Oxygen and Glucose
The measurement of fluorescence quenching activity of [Ru(L)3] with 4,7-diphenyl1,10 phenanthroline (dip) on silica gel and embedded in polystyrene polymers for the determination of dissolved oxygen using fiber optic probe is described here. The system is extended by immobilization of glucose oxidaze (GOD) for the determination of glucose. The objective of the work is to conquer the leaching an...
متن کاملMicro-patterning of Polymer-based Optical Oxygen Sensors for Lab-on-Chip Applications
Soft-lithography and plasma etching with reactive ions were used to fabricate a polymer microfluidic cell-culture bioreactor with integrated optical oxygen sensor. Platinum(II) octaethylporphyrin ketone (PtOEPK) suspended in a microporous polystyrene (PS) matrix was spin-coated to form sensor films of variable thickness from 1.1 μm to 400 nm on glass substrates. Sensor films were found to be sm...
متن کاملFirst experience with a novel luminescence-based optical sensor for measurement of oxygenation in tumors
Background. The purpose of this preliminary study was to evaluate a novel luminescence-based fiber-optic sensor (OxyLite system) for the measurement of partial pressure of oxygen (pO2) in tumors and for the detection of changes in pO2 as a function of time. The new method was used simultaneously with the laser Doppler flowmetry method for the measurement of relative tissue perfusion. Materials ...
متن کاملMeasurement of tumor oxygenation: a comparison between polarographic needle electrodes and a time-resolved luminescence-based optical sensor.
A novel oxygen sensor which does not rely on electrochemical reduction has been used to measure the oxygenation of the murine sarcoma F in a comparative study with an existing polarographic electrode that is available commercially. The prototype luminescence sensor yielded an oxygen distribution comparable with readings made using a pO2 histograph. The percentage of regions detected that had a ...
متن کامل