Validity of autorefraction after cataract surgery with multifocal ReZoom intraocular lens implantation.

نویسندگان

  • Gonzalo Muñoz
  • César Albarrán-Diego
  • Hani F Sakla
چکیده

PURPOSE To evaluate the clinical utility of spherocylindrical automated refraction (AR) compared with subjective manifest refraction (MR) after cataract surgery with implantation of ReZoom refractive multifocal intraocular lenses (IOLs) (Advanced Medical Optics, Inc.). SETTING Private Practice. METHODS This prospective nonrandomized interventional study consisted of 72 patients with bilateral cataract and a potential visual acuity of at least 20/40. Patients had bilateral nonsimultaneous cataract surgery and implantation of a ReZoom IOL. Manifest refraction was performed in all patients followed by 3 consecutive measurements using the Topcon KR-8000 autorefractor with nondilated and dilated pupils. Assessment of repeatability of multiple consecutive ARs and comparison of the AR and MR using power vector analysis were performed at the 6-month follow-up. The main outcome measures were the correlation between AR and MR with sphere, spherical equivalent, and astigmatism as well as the repeatability of AR before and after dilation with phenylephrine 10%. RESULTS Repeatability analysis showed that the initial nondilated AR was not significantly different from the mean of the 3 refractions for nondilated and dilated measurements. The mean difference between the initial AR and the MR was -0.84 +/- 0.62 diopters (D) for sphere (SD), -1.00 +/- 0.61 D for spherical equivalent, and -0.06 +/- 0.19 D and -0.01 +/- 0.17 D, respectively, for J(0) and J(45), the 2 components of astigmatism. Linear regression of AR versus MR data showed poor correlation for sphere (R(2) = 0.4852) and spherical equivalent (R(2) = 0.5529), whereas the correlation for the 2 astigmatic components of vector analysis was excellent (J(0), R(2) = 0.8881; J(45), R(2) = 0.8640). Correlation was better when the MR residual refractive defect was higher. CONCLUSIONS Although autorefraction showed excellent agreement with subjective refractive astigmatism, correlation with spherical values was poor, with a trend toward more negative values. Autorefraction after ReZoom IOL implantation can be used as a good starting point for subjective refraction of astigmatism; however, spherical values should be underestimated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multifocal intraocular "mix and match" lenses.

The new generation multifocal lenses provide the surgeon with several options to meet the specific visual needs and desires of patients. A revolution in presbyopia surgery is being driven by two multifocal intraocular lenses, ReStor and ReZoom. Combined implantation of the ReZoom multifocal lens in nondominant eye and ReStor multifocal lens in dominant eye has been demonstrated to produce stati...

متن کامل

Comparison of diffractive and refractive multifocal intraocular lenses in presbyopia treatment.

Multifocal intraocular lenses (MFIOL) enable good near and far vision after cataract surgery. Excellent results with cataract patients encouraged ophthalmologists to implant MFIOL after clear lens extraction (CLE). There are two types of MFIOL: diffractive and refractive. In our prospective study we compared clinical outcomes after CLE and bilateral implantation of diffractive (Tecnis Multifoca...

متن کامل

Visual Results Following Implantation of a Refractive Multifocal Intraocular Lens in One Eye and a Diffractive in the Contralateral Eye

Objectives To assess the visual outcomes in patients who underwent cataract surgery with multifocal intraocular lens (IOL) implantation using a "mix and match" approach. Materials and Methods Twenty patients (40 eyes) were involved in this prospective, nonrandomized study. Refractive multifocal IOLs (ReZoom NXG1) were implanted in patients' dominant eyes and diffractive multifocal IOLs (Tecni...

متن کامل

Prospective functional and clinical comparison of bilateral ReZoom and ReSTOR intraocular lenses in patients 70 years or younger.

PURPOSE To compare clinical outcomes, functional vision, and spectacle freedom in patients 70 years or younger with bilateral ReSTOR (Alcon Laboratories) or ReZoom (Advanced Medical Optics) intraocular lenses (IOLs). SETTING Private practice, Los Altos, California, USA. METHODS Thirty patients had nonrandomized bilateral implantation of a ReZoom or ReSTOR multifocal IOL. Patients were 70 ye...

متن کامل

Non-organic Visual Loss in Patients with Multifocal Intraocular Lenses

PURPOSE To report non-organic visual loss (NOVL) following cataract surgery with multifocal intraocular lens (IOL) implantation. METHODS After reviewing consecutive cases of NOVL diagnosed by a single neuro-ophthalmologist over a one year period, two patients reported herein attributed their visual symptoms to cataract surgery and multifocal IOL implantation. RESULTS In both patients variab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 33 9  شماره 

صفحات  -

تاریخ انتشار 2007