Sectional Impression Technique and Magnet Retained Two-Piece Obturator for Maxillectomy Patient with Trismus

نویسندگان

  • Pravinkumar G. Patil
  • Smita P. Patil
  • Rahul S. Kulkarni
چکیده

This article describes technique to make the sectional impression of the maxillectomy defect of a patient with the reduced mouth opening. The cast generated after pouring the impression is duplicated twice to fabricate the defect component and the palatal base-plate component separately. Both the components were then oriented and attached with the help of a pair of the magnets. This magnet retained obturator facilitates the insertion and removal of the prosthesis in two separate pieces in restricted mouth opening situation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Oromaxillary Prosthetic Rehabilitation of a Maxillectomy Patient Using a Magnet Retained Two-Piece Hollow Bulb Definitive Obturator; A Clinical Report

Resection of a malignant lesion involving the maxilla produces severe oromaxillary defect that can seriously jeopardize the normal phonetics of the patient. These defects are effectively managed by well-designed and fabricated obturator. This paper discusses the oromaxillary prosthetic rehabilitation of a maxillectomy patient using a magnet retained two-piece hollow bulb definitive obturator.

متن کامل

A Comprehensive Prosthodontic Management of

Discussion: Prosthodontic rehabilitation of patients with maxillectomy is a challenge as it involves restoring speech, deglutition, mastication and respiration. This clinical report describes a comprehensive prosthodontic management of a young girl treated for a subtotal maxillectomy due to intraosseous mucoepidermoid carcinoma. The prosthodontic management that was carried out right from the s...

متن کامل

Prosthetic rehabilitation of a complete bilateral maxillectomy patient using a simple magnetically connected hollow obturator: a case report.

AIM The purpose of this clinical report is to present a description of the prosthetic rehabilitation of a bilateral complete maxillectomy patient using a two piece magnetically connected prosthesis. BACKGROUND A complete bilateral maxillectomy defect presents a considerable reconstructive challenge for the prosthodontist. It results in devastating effects on cosmetic, functional, and psycholo...

متن کامل

Fabricating a Maxillary Obturator Using an Intraoral Digital Impression: A Case History Report.

Digital impressions can be a useful option that reduces patient discomfort and simplifies clinical procedures such as accurate impression recordings. In this report, a patient with a partial maxillectomy was managed with a metal frame fabricated from a digital impression through an intraoral scanner. The final impression employed the altered cast technique for the fabrication of the obturator.

متن کامل

Implant-supported obturator overdenture for extensive maxillary resection patient: a clinical report.

This clinical report presents an implant-retained obturator overdenture solution for a Prosthodontic Diagnostic Index Class IV maxillectomy patient with a large oronasal communication and severe facial asymmetry, loss of upper lip and midfacial support, severe impairment of mastication, deglutition, phonetics, and speech intelligibility. Due to insufficient bone support to provide satisfactory ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014