Determinants of pulse pressure.

نویسندگان

  • N Stergiopulos
  • N Westerhof
چکیده

We have searched to define the major arterial parameters that determine aortic systolic (Ps) and diastolic (Pd) pressure in the dog. Measured aortic flows were used as input to the 2-element windkessel model of the arterial system, with peripheral resistance calculated as mean pressure divided by mean flow and total arterial compliance calculated from the decay time in diastole. The windkessel model yielded an aortic pressure wave from which we obtained the predicted systolic (Ps,wk) and diastolic (Pd,wk) pressures. These predicted pressures were compared with the measured systolic and diastolic pressures. The measurements and calculations were performed for 7 dogs under control conditions during aortic occlusion at 4 locations (the trifurcation, between the trifurcation and diaphragm, the diaphragm, and the proximal descending thoracic aorta) and during occlusion of both carotid arteries. Under all conditions studied, the predicted systolic and diastolic pressures matched the experimental ones very well: Ps,wk=(1.000+/-0.0055) Ps with r=0.958 and Pd,wk=(1.024+/-0.0035) Pd with r=0.995. Linear regression for pulse pressure (PP) resulted in PPwk=(0.99+/-0.016) PP with r=0.911. We found the accuracy of prediction equally good under control conditions and in the presence of aortic or carotid artery occlusion. Multiple regression between pulse pressure and arterial resistance and total arterial compliance yielded a poor regression constant (R2=0.19), suggesting that the 2 arterial parameters alone cannot explain pulse pressure and that flow is an important determinant as well. We conclude that for a given ejection pattern (aortic flow), 2 arterial parameters, total arterial resistance and total arterial compliance, are sufficient to accurately describe systolic and diastolic aortic pressure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Passive Movements of Lower Extremity on Hemodynamic Parameters of the Patients under Ventilator

Aims: The present study was conducted with the aim of determining the effect of passive movements on hemodynamic parameters, including systolic blood pressure, diastolic blood pressure, mean arterial pressure, pulse, and pulse pressure of patients under ventilation. Materials & Method: In this controlled clinical trial, 64 patients under ventilation in Kohgiluyeh and Boyer-Ahmad University of ...

متن کامل

Determinants of brachial artery mean 24 h pulse pressure in individuals with Type II diabetes mellitus and untreated mild hypertension.

Brachial artery pulse pressure is a predictor of (cardiovascular) morbidity, but its determinants in individuals with Type II diabetes and untreated mild hypertension have not been elucidated. We therefore cross-sectionally investigated determinants of brachial artery mean 24 h pulse pressure in 60 individuals (40 males; age, mean +/- S.D., 57.8 +/- 7.5 years) with Type II diabetes [median diab...

متن کامل

Relationship between some indices of cardiovascular functions and pulse pressure as a predictor index for heart diseases: a case-control study

Background: Pulse pressure has recently been considered as a predictor of coronary heart disease. The difference between systolic and diastolic blood pressure is called pulse pressure. Various factors including increased age, vascular stiffness, stenosis, and hypertension are associated with pulse pressure. The present study, therefore, aimed to investigate the relationship between some cardiov...

متن کامل

Genetic determinants of systolic and pulse pressure in an intercross between normotensive inbred rats.

By continuous monitoring of abdominal aortic blood pressure via telemetry in conscious rats, we have observed that systolic, diastolic, and pulse pressures of male Brown-Norway rats were all significantly lower than that of male Wistar-Kyoto rats, despite the fact that all of the values in both strains were within normotensive ranges. Further analyses performed in 166 animals from the progeny o...

متن کامل

Designing and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals

Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and M...

متن کامل

Investigation of Pressure Pulse Distribution in Porous Media

  Diffusivity equation commonly used for pressure distribution prediction in porous media results from substituting equation of state and continuity equation in Navier-Stokes momentum equation. From mathematical point of view this equation format shows infinite propagation speed for pressure pulse through porous media, which is physically impossible. This issue may caused by numerous assumption...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hypertension

دوره 32 3  شماره 

صفحات  -