Nitric Oxide Detection with Glassy Carbon Electrodes Coated with Charge-different Polymer Films
نویسندگان
چکیده
Trace amounts of nitric oxide (NO) have been determined in aqueous phosphate buffer solutions (pH=7.4) by using a glassy carbon electrode coated with three charge-different polymer films. The glassy carbon electrode was coated first with negatively charged Nafion film containing tetrakis(pentafluorophenylporphyrin) iron(III) chloride (Fe(III)TPFPP) as the NO oxidation catalyst, and then with positively charged poly(acrylamide-co-diallyldimethylammonium chloride) (PADDA) and with neutral poly(dimethylsiloxane) (silicone) at the outermost layer. This polymer-coated electrode showed an excellent selectivity towards NO against possible concomitants in blood such as nitrite, ascorbic acid, uric acid, and dopamine. All current ratios between each concomitant and NO at the cyclic voltammogram was in 10 ~ 10. This type of electrode showed a detection limit of 80 nM for NO. It was speculated from the electrochemical study in methanol that high-valent oxoiron(IV) of Fe(TPFPP) participated in the catalytic oxidation of NO.
منابع مشابه
Reduction of Nitric Acid to Hydroxylamine at Glassy Carbon Surfaces Modified by the Reduction of p-Phenylenediamine and p-Aminophenol in 1.0 M Nitric Acid A Scanning Electrochemical Microscopy Study
The scanning electrochemical microscope ~SECM! was used to study the electrochemical reduction of nitric acid to hydroxylamine at modified glassy carbon ~GC! electrodes. The GC surface was modified by holding it at a negative potential in solutions of p-aminophenol, or p-phenylenediamine in 1.0 M nitric acid. The generated products were detected in generation/collection experiments with an SECM...
متن کاملXIX. Electrochemical Behavior at Polypyrrole-Nafion and Polypyrrole-Clay Thin Films on Glassy Carbon Electrodes
Biconductive films, involving the incorporation of an electronically conductive phase within an ionically conductive one, on glassy carbon electrode surfaces have been prepared by electropolymerization to form polypyrrole (PP) in matrices of Nation and the clay, hectorite. These films display electronic conductivity and higher stability than films of PP alone. Electrochemical studies of several...
متن کامل3D printed microfluidic devices with integrated versatile and reusable electrodes.
We report two 3D printed devices that can be used for electrochemical detection. In both cases, the electrode is housed in commercially available, polymer-based fittings so that the various electrode materials (platinum, platinum black, carbon, gold, silver) can be easily added to a threaded receiving port printed on the device; this enables a module-like approach to the experimental design, wh...
متن کاملCyclic Voltammetry of Cobalt Chloride with L- Carrageenan (LK) Using Glassy Carbon Electrode
The redox behavior cobalt chloride was studied voltammetrically in presence and absence of L- Carrageenan (LK) natural polymer using glassy carbon electrodes in 0.1 M KCl supporting electrode. Scan rates are studied for the redox behaviors for CoCl2 alone or in presence of L- Carrageenan (LK) natural polymer. Stability constants for the interaction of cobalt ions with L - Carageenan (LK) natura...
متن کاملDeveloped Method Application for Nitrite Ion (NO2¯ ) Analysis of Tib -186 Macrophage Like Cell Lines by Rapid Isocratic HPLC System with High Sensitive Glassy Carbon Electrochemical Detector
A rapid isocratic method of high performance liquid chromatography system (HPLC) with a glassy carbon working electrode of electrochemical detector is set up for quantitative detection of trace amount of nitrite ion (NO2¯) in aqueous protein containing cell lysate, cell media, plasma, serum, urine and other body fluids. The solid extraction reversed phase cartridges ...
متن کامل